14
Fault finding / Messages
When lights are flashing, you should look
for the reason, and act before using the
toilet. Immediate action is required when
irregularities such as odours, poor incine-
ration or system failures occur, in order
to avoid consequential damage and unne-
cessary repair costs.
During cleaning and fault finding, resetting the electronic unit may sometimes be helpful. Do this by pushing the start button, this
will cause a short beep to be heard. Hold down the button for about 8 seconds until a long beep is heard, then release button.
Error
Red light
Error
Red light
Combustion
Yellow light
Combustion
Yellow light
Start button
Start button
Start button
Status
messages
Power
Green light
Power
Green light
Error
Error
message
(Comfort)
Red Yel. Sound What to doGreen
Ash container
must be emptied
Remove and empty ash container.
Remove and empty ash container.
Adjust position of ash container.
Empty the
ash container
Toilet locked
container full
Ash container
must be emptied,
toilet locked.
Temperature
sensor is faulty,
shortcircuited or
broken.
Heating circuit
interrupted
Error
heating circuit
No mains
power
Hatch is jammed
/ bag is jammed
Toilet lid opens. Close toilet lid.
Lid is open
Error
temp.sensor
Ventilation fan error
Ash container
in wrong
Ash pan
out of position
Error fan
Flashing
Flashing Flashing
Flashing
Flashing
Flashing
Flashing
Flashing
Flashing Flashing
Flashing
Lamp
on
Lamp
on
Lamp
off
Continuous
Continuous
3
beeps
3
beeps
3
beeps
3
beeps
every 10. sec
10
beeps
10
beeps
1
1
1
2
3
1
2
1
1
2
1
1
1
No power
Battery mode
Error hatch
mechanism
Connect mains power.
Open and close toilet lid.
Start incineration.
Check fan for obstructions.
Reset toilet by holding down ’start’ button
for about 8 seconds until long beep is
heard. Open and close toilet lid. Start incine-
ration. If error persists, disconnect plug and
call for service.
3
When toilet is hot: Reset toilet. Push ’start’
button, but do not put a new bag in the
bowl. If unsuccessful, reset toilet, put new
bag in bowl, pour in 3 cups of water and
push ’start’ button. If still unsuccessful, wait
until toilet has cooled (fan stopped). When
toilet is cool: Reset toilet, open lid and push
’start’ button. Hatch opens and pieces of
paper may be removed manually.
Disconnect mains plug.
Wait 15 minutes.
Check temperature sensor on right hand
side of toilet. Unscrew grey plug. Push on
fuse inside with finger, do not use any
sharp objects. A click is heard if fuse had
triggered. If so, check inlet/outlet air. If
fuse had not been triggered, call for service.
Reset toilet by holding down ’start’ button
for about 8 seconds until a long beep is
heard. Open and close lid. Start incineration.
If error persists, disconnect mains plug and
call for service.
2