VCC-G20X30B Rev. 900-731-31-00
©2012 CIS Corporation. All rights reserved.
15
Camera HD
CCD Output
102
Black Transmit Dummy Pixels
40 164 325 1034
Effective Pixels
Horizontal Scanning(1H) = 1270clk(42.33μs)
7322
151
(0.73μs)
(3.4μs)
(2.43μs)
(5.03μs)
Horizontal Blanking
246clk(8.2μs)
Video Output
Video Active Period
1024clk(34.13μs)
clk = 30MHz
CCD Output
BlackTransmit
8 7
9
779
Effective Lines
Vertical Blanking
Video Output
Camera VD
11
2
1
778
779
28H
Video Active Period
768H
V = 796H (29.68Hz)
1H = 42.33μs
2
10
12
77
WEN Output
1H
Invalid
(Normal Shutter Mode = H Level)
7. Timing Chart
7.1. Horizontal Timing
7.2. Vertical Timing
7.2.1. Full Frame Scan Mode
7.2.2. Binning Scan Mode
CCD Output
BlackTransmit
4 4
9
389
Effective Lines
Vertical Blanking
Video Output
Camera VD
27+28
3+4
1+2
765+766
767+768
28H
Video Active Period
370H
V = 398H (59.35Hz)
1H = 42.33μs
31+32
29+30
769+770
779
1
WEN Output
1H
(Normal Shutter Mode = H Level)
Invalid