VCC-G20X30B Rev. 900-731-31-00
©2012 CIS Corporation. All rights reserved.
6
Item Specification
Shutter speed
variable range
<Normal Shutter Mode>
OFF(1/30), 1/125, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000s
<Trigger Shutter Mode>
OFF(1/60), 1/125, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000s
Pulse Width: 9μ250ms
Shutter Mode
Normal Shutter Mode, Restart/Reset Mode, Fixed Trigger Shutter Mode, and
Pulse Width Trigger Shutter Mode
Safety/Quality
standards
UL: Conform to UL Standard including materials and others.
RoHS: Conform to RoHS
CE: Conform to EN55022:2010 (Class B) for Emission
Conform to EN61000-6-2:2005 for Immunity
To be applied to FCC Class A digital Device
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Durability
Vibration
Acceleration 98 m/s
2
(10.0G)
Frequency
20200 Hz
Direction XYZ 3 directions
Testing time 120 min for each direction
Shock
No malfunction shall be occurred with 980m/s
2
(100G) for ±X,
±Y, ±Z, 6 directions. (without package)
Operation environment
Temperature
Operation guaranteed: -5+45
Performance guaranteed: 0+40
Humidity
RH 2080% with no condensation
Storage environment
Temperature
-25 +60
Humidity
RH 2080% with no condensation