EasyManua.ls Logo

citEcar Bubble Buddy - User Manual

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
citEcar Bubble Buddy
Owners Manual
Sold and Distributed by
citEcar LLC
www.citEcarEV.com
Phone: (866) 542-8677
Fax: (843) 556-4080

Questions and Answers

  • D
    David JacobsonSep 9, 2025
    Why is the internal voltage too low at startup in my citEcar Bubble Buddy?
    • J
      Jacob DavisSep 9, 2025
      If the internal voltage is too low at startup in your citEcar Golf Cars, there may be an external short or leakage path to B- on the external B+ connection. Check for external shorts or leakage. Alternatively, the controller might be defective, requiring replacement.
  • M
    Matthew WallaceAug 23, 2025
    What to do if my citEcar Golf Cars motor stalls?
    • T
      Tabitha GilbertAug 23, 2025
      If your citEcar Golf Cars motor stalls, it could be due to several reasons. The slope might be too steep for the vehicle's weight, so check and reduce the slope if needed. The motor could be mechanically locked, requiring inspection and freeing. A failure in the EM brake wiring could also be the cause, so check the EM brake wiring. Lastly, a defective speed sensor can cause this issue, so consider replacing the speed sensor.
  • C
    Christopher GriffinAug 25, 2025
    Why am I getting an overvoltage error on my citEcar Bubble Buddy Golf Cars?
    • K
      kberryAug 25, 2025
      Overvoltage in your citEcar Golf Cars can happen if the battery voltage is under voltage cutback threshold. Make sure to check the battery voltage. It could also be because the vehicle is being operated with the charger still attached, so remove the charger. Another reason might be that the battery was disconnected during regenerative braking; in this case, reconnect the battery properly.
  • S
    stephanie93Aug 27, 2025
    What causes thermal cutback in citEcar Golf Cars?
    • J
      jeremy55Aug 27, 2025
      Thermal cutback in citEcar Golf Cars can occur if the temperature is greater than 85°C or less than -25°C. Ensure the vehicle operates within specified temperature limits. It may also happen if there is excessive load on the vehicle, so reduce the load. Improper mounting of the controller can also cause this, so mount the controller properly. Finally, operating in extreme environments can lead to thermal cutback, so avoid extreme operating conditions.
  • T
    Tiffany LewisAug 27, 2025
    Why is the main contactor coil held low in my citEcar Bubble Buddy?
    • R
      Robert MedinaAug 28, 2025
      If the main contactor coil is held low in your citEcar Golf Cars, it could be due to the main contactor missing or the wire to the coil being open. Check for the main contactor and repair the wiring. Alternatively, the controller might be defective, requiring replacement.
  • J
    Jeremy BartlettAug 29, 2025
    How to fix SRO fault in citEcar Bubble Buddy?
    • T
      Tonya GarciaAug 29, 2025
      If the key switch is not off during power-up or is shorted in your citEcar Golf Cars, it can cause a SRO fault. Ensure the key switch is off during power-up. If the issue persists, replace the key switch.
  • J
    Justin PriceSep 17, 2025
    Why is the aux (EM brake or WalkAway™ relay) driver coil held low in citEcar Bubble Buddy Golf Cars?
    • E
      Elizabeth PattersonSep 18, 2025
      If the aux (EM brake or WalkAway™ relay) driver coil is held low in your citEcar Golf Cars, it could be due to an aux output short to ground. Inspect for shorts to ground. Alternatively, the controller might be defective and needs to be replaced.
  • S
    Stephen LynchSep 19, 2025
    What to do if the circuit breaker or fuse is open in the WalkAway™ circuit of my citEcar Golf Cars?
    • B
      Belinda TownsendSep 22, 2025
      If the circuit breaker or fuse is open in the WalkAway™ circuit of your citEcar Golf Cars, the breaker/fuse may have tripped or is open. Reset or replace the breaker/fuse. The breaker/fuse may also be defective, so replace the defective breaker/fuse. Finally, the relay/fuse sensor line may be broken, so repair the broken relay/fuse sensor line.
  • R
    Robert ZunigaSep 8, 2025
    How to fix a welded main contactor in citEcar Bubble Buddy?
    • F
      Frank ThompsonSep 8, 2025
      A welded main contactor in your citEcar Golf Cars can occur if the main contactor is stuck closed. Inspect and free the main contactor. Alternatively, the main contactor driver might be shorted, requiring you to replace the main contactor driver.
  • J
    James CampbellSep 4, 2025
    Why is the aux (brake, relay) coil missing in my citEcar Bubble Buddy Golf Cars?
    • A
      Ashley LoganSep 5, 2025
      If the aux (brake, relay) coil is missing in your citEcar Golf Cars, it could be because the aux coil is open or not connected. Connect or replace the aux coil to resolve this issue.

Summary

1. Overview

2. Controls

Control Functions: Ignition and F;R Switch

Details operation of the ignition key and forward/reverse selector switch.

3. Safe Operation Instructions

General Vehicle Safety

Crucial safety guidelines before and during vehicle operation.

4. Operation

Starting and Stopping Procedures

Step-by-step guide for starting and stopping the vehicle safely.

5. Maintenance

5.1 Battery Maintenance

Procedures for cleaning, checking, and recharging the vehicle's battery.

5.5 Diagnostics and Troubleshooting

Overview of diagnostic features and troubleshooting guides for system issues.

7. Running-in of New Vehicle

8. Periodic Maintenance Charts

10. Wiring Diagram

citEcar Bubble Buddy Specifications

General IconGeneral
Seating Capacity2
Voltage48V
Battery Capacity100 Ah
Max Speed25 mph
Range per Charge50 miles
Dimensions (L x W x H)96" x 48" x 72"
Tire Size18x8.5-8
MotorElectric