7
The second hand changes to a two second
interval movement to indicate insufcient recharging.
Eveninsuchacase,thewatchkeepscorrecttime,butabout
4 days after the two second interval movement begins, the
watch will stop.
Afterexposingthewatchtolight,rechargingtakesplaceand
the watch returns to one second interval movement.
Two second interval
movement
2 sec
2 sec
■
Quick Start Function
The watch will stop if it is completely discharged.
It will begin to operate soon after it is exposed to light.
(However,thetimetostartmayvaryaccordingtothebrightnessofthelight.)
■
Overcharge Prevention Function
You can recharge your watch without worry.
Once the special energy storage cell is fully charged, the overcharge prevention
function comes into operation and prevents over-charging of the energy storage cell.
■
Insufcient Charge Warning Function