Citrix ADC MPX
Health
attribute Unit
Lower
Non-
Recoverable
Lower
Critical
Lower
Non-
Critical
Upper
Non-
Critical
Upper
Critical
Upper
Non-
Recoverable
System
Temp
degrees C -9.000 -7.000 -5.000 80.000 85.000 90.000
Peripheral
Temp
degrees C -9.000 -7.000 -5.000 80.000 85.000 90.000
PCH
Temp
degrees C -11.000 -8.000 -5.000 90.000 95.000 100.000
FPC_Temp
1
degrees C - NA - - NA - - NA - 66.000 70.000 75.000
FPC_Temp
2
degrees C - NA - - NA - - NA - 72.000 76.000 82.000
FPC_Temp
3
degrees C - NA - - NA - - NA - 72.000 76.000 82.000
HDDBP_Temp
1
degrees C - NA - - NA - - NA - 72.000 76.000 82.000
HDDBP_Temp
2
degrees C - NA - - NA - - NA - 72.000 76.000 82.000
FAN 1 RPM - NA - 1980.000 - NA - - NA - - NA - - NA -
FAN 2 RPM - NA - 1980.000 - NA - - NA - - NA - - NA -
FAN 3 RPM - NA - 1980.000 - NA - - NA - - NA - - NA -
FAN 4 RPM - NA - 1980.000 - NA - - NA - - NA - - NA -
FAN 5 RPM - NA - 1980.000 - NA - - NA - - NA - - NA -
FAN 6 RPM - NA - 1980.000 - NA - - NA - - NA - - NA -
FAN 7 RPM - NA - 1980.000 - NA - - NA - - NA - - NA -
FAN 8 RPM - NA - 1980.000 - NA - - NA - - NA - - NA -
PS_1
Status
discrete - NA - - NA - - NA - - NA - - NA - - NA -
PS_1 FAN RPM - NA - - NA - - NA - - NA - - NA - - NA -
PS_1
Temp
degrees C - NA - - NA - - NA - - NA - - NA - - NA -
PS_2
Status
discrete - NA - - NA - - NA - - NA - - NA - - NA -
© 19992022 Citrix Systems, Inc. All rights reserved. 190

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX 5900 and is the answer not in the manual?

Citrix ADC MPX 5900 Specifications

General IconGeneral
BrandCitrix
ModelADC MPX 5900
CategoryNetwork Hardware
LanguageEnglish

Related product manuals