C5HP16EC
SPECIAL FEATURES : AIR CONDITIONING SYSTEM (R 134.a)
Condenser with integral reservoir (continued)
WARNING : The reservoir (6) contains a drying agent. As soon as the black protection is removed, the reser-
voir must be mounted in the base (8), otherwise there is a risk of damaging the air conditioning circuit.
Screwing the reservoir (6) into the base (8).
- Screw the reservoir (6) manually, until the neck of the reservoir (6) is in contact with the bottom of the
base (8).
- Tighten with a torque spanner and tool [2] at (2) to 1.3 ± 0.1 m.daN.
Fitting the plastic bracket. (New, from the replacement parts kit).
Proceed in the opposite order to removal, tighten the screw (3) to 0.15 m.daN.