EasyManua.ls Logo

CKD ABSODEX AX1022 - AX-OPX DeviceNet Slave Unit; DeviceNet Slave Unit Features; DeviceNet Slave Unit How to Order; DeviceNet Slave Unit Appearance

Default Icon
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
68
AX-OPX-7D
Serial transmission slave unit
DeviceNet
Serial transmission slave unit
CC-Link/DeviceNet
Common with GS/GH/S/H type driver
Explanation of appearance
The direct drive actuator is used with DeviceNet by installing it on the
driver's I/O connector (CN3).
Major reductions in wiring
I/O point
16 inputs, 14 outputs
Whether to hold output if a communication error occurs or to turn all
points off is selected with the HLD/CLR switch.
Three transmission speeds are selectable.
An external emergency stop input (b contact) is connected serially to
the emergency stop signal with serial communication.
CE marking
Features
Descriptions Specifications
Slave unit power
AX driver power
Communication power
Working ambient temperature range
Working ambient humidity range
Atmosphere
Vibration resistance
Weight
24 VDC ±10% and 100mA or less
24 VDC +10%, -5% or 450mA or less
11 to 25 VDC 50mA or less
5 to 50˚C
30 to 85%RH (with no dew condensation)
Without corrosive gas and dust
4.9m/s
2
0.15kg
Common specifications
Descriptions Specifications
Communication subject
Communication speed
Output No.
Input No.
Other inputs
Output insulation type
Operating indication
Occupied byte number
Setting switch
DeviceNet conformed
125k/250k/500k bps
(select with a switch.)
14 points
16 points
Pulse string, emergency stop
Photo coupler insulation
LED (power and communication state display)
Input: 2 bytes, output: 2 bytes
Output mode (HLD/CLR),
Node address and communication speed
Performance specifications
How to order
Accessory (plug)
1) MSTB2.5/5-STF-5.08AUDVM (Phoenix contact) 1 pc.
2) BL3.5/2F (Weidmüller) 2 pcs.
3) ZHR-6 (JST MFG CO. LTD.) 1 pc.
Blank
D02
Standard
Cable for pulse string input (2m) attached
Symbol
Descriptions
AX-OPX-7D
D02
Model Model no. of options
Note: When using emergency stop input from an external source, or when
operating with a pulse string from an external pulse generator,
designated the option model No.
1
2
4
8
16
32
1
0
DR NA
H C
AX-OPX-
7D
0V
A
X
p
o
w
e
r
2
4
V
NS MS
Node address setting switch
Setscrew (1 each on both top and bottom)
Guard
Emergency stop pulse string
input connector
Serial communication signal
line connector
Slave unit power
Power for AX driver
Communication speed
setting switch
Output mode setting switch
Name plate
Operating indication LED
(including communication power line)
Top view
(Inside of cover)

Related product manuals