67
AX-OPX-7G
Serial transmission slave unit
CC-Link
Common with GS/GH/S/H type driver
Connect the direct drive actuator to a Mitsubishi Electric PLC MELSEC-
A or QnA Series field network CC-Link (ver. 1.10) by installing it on the
driver's I/O connector (CN3).
Major reductions in wiring
I/O point
16 inputs, 14 outputs
Whether to hold output if a communication error occurs or to turn all
points off is selected with the HLD/CLR switch.
Five transmission speeds are selectable.
An external emergency stop input (b contact) is connected serially to
the emergency stop signal with serial communication.
Features
Descriptions Specifications
Slave unit power
AX driver power
Working ambient temperature range
Working ambient humidity range
Atmosphere
Vibration resistance
Weight
24 VDC ±10% and 100mA or less
24 VDC +10%, -5% or 450mA or less
5 to 50˚C
30 to 85% RH (with no dew condensation)
Without corrosive gas and dust
4.9m/s
2
0.15kg
Common specifications
Descriptions Specifications
Communication subject
Transmission speed
Output No.
Input No.
Other inputs
Output insulation type
Operating indication
Occupied unit No.
Setting switch
CC-Link system (Ver1.10) compliant
156K/625K/2.5M/5M/10M bps
(select with a switch.)
14 points
16 points
Pulse string, emergency stop
Photo coupler insulation
LED (only display of slave unit power and communication state)
1 station (remote I/O station)
Station no., transmission speed, HLD/CLR,
Terminal ON/OFF
Performance specifications
Explanation of appearance
AX-OPX-7G
D02
How to order
Accessory (plug)
1) BLZ5.08/5FAU (Weidmüller) 1 pc.
2) BL3.5/2F (Weidmüller) 2 pcs.
3) ZHR-6 (JST MFG CO. LTD.) 1 pc.
Note: When using emergency stop input from an external source, or when
operating with a pulse string from an external pulse generator,
designated the option model No.
Blank
D02
Standard
Cable for pulse string input (2m) attached
Symbol
Descriptions
Model Model no. of options
3
4
6
7
9
2
1
0
8
5
3
4
6
7
9
2
1
0
3
4
6
7
9
2
1
0
5
8
8
5
RATE
.
ST No.
END
C H
B
1
X
1.0
X
A
X
-
O
P
X
-
7
G
0V
A
X
p
o
w
e
r
2
4
V
SLD DG DB DAFG
L ERR L RUN RD SD PW
Station No. setting switch
Setscrew (1 each on both top and bottom)
Guard
Emergency stop pulse string
input connector
Serial communication signal
line connector
Slave unit power
Power for AX driver
Transmission speed setting switch
Output mode setting switch
Terminal station setting switch
Name plate
Operating indication LED
Top view