L.8
BLEED AIR FROM THE PNEUMATIC
BRAKING: CHECK
The aim of this operation is to eliminate water from the pneumatic
circuit. It must be carried out just after the engine stops, when the
circuit is still under pressure.
Press the drain valve (E) until all the air is eliminated.
PNEUMATIC BRAKING CONNECTORS:
CHECK - GREASING
- Check the condition of connectors (F), (G) et (H), then have
them replaced by your approved CLAAS agent if necessary.
- Grease the connectors regularly to prolong the life of the
seals.
HYDRAULIC FLUID LEVEL: CHECK
Note: Before checking the fluid level, the engine must have
been stopped for a minimum of 5 minutes and the linkage
arms must be in the low position.
- Position the tractor on a flat horizontal surface.
- Check the fluid level with dipstick (J).
I - Normal level.
II - Top up as soon as possible.
III - Top up before restarting the engine.
Important:
- The oil level must never fall below the lower mark (III).
- If using hydraulic implements that require a large quantity
of fluid in their power supply system (hydraulic motors,
large capacity cylinders), top the fluid up to the top
marker (I). The quantity of oil necessary between mark (III)
and mark (I) is about 8 l.
- Failure to carry out these instructions can in some
circumstances cause considerable damage to the power
transmission.
The oil is topped up via cap (L).