Nitrogen and pure air generator NitroAir
19
6.8.2.
Setting the Minimum Air Pressure alarm
OUTPUT MINIMUM PRESSURE
xx.x bar
This value represents the minimum air pressure value in the built-in reservoir of
the generator, under which the alarm UNSUFFICIENT AIR PRESSURE is acti-
vated.
To access from the main menu press the Function key . This value can be in-
creased or decreased pressing the Function key and pressing the up arrow
key or down arrow key at the same time
To go back on main page, press for some second the Function key .
e
The default value is 6.0 bar.
6.8.3.
Regulation of the output air pressure
The regulator is located on the rear of the generator (see par. 3.3.2).
Rotate the control knob to regulate the pressure to the desired value (clockwise
to increase pressure), displaying it on the gauge (AIR) on the front panel of the
grenerator (see par. 3.3.1).
e
The default regulation is 0.0 bar (vent closed).
6.8.4.
Regulation of the minimum Nitrogen pressur alarm
To access to the parameter press the function key from the main menu.
MINIMUM OUTPUT PRESSURE
xx.x bar
This value represents the Nitrogen pressure on the internal tank under which the
alarm UNSUFFICIENT NITROGEN PRESSURE is activated.
To access from the main menu, press the function key . This value can be
increased or decreased by pressing the Function key while selecting the up
arrow key or the down arrow key .
To go back on the main page, press the function key f for some seconds.
e
The default value is 6.0 bar.
6.8.5.
Nitrogen output pressure regulation
The regulator is positioned on the rear of the generator (see par. 3.3.2).
Rotate the control knob to regulate the pressure to the desired value (clockwise
to increase pressure), indicated by a gauge (NITROGEN) on the front of the in-
strument (see par. 3.3.1).
e
The default regulation is 0.0 bar (vent closed).