EN
Warewasher does
not heat up.
Warewasher not
turned on.
Check that the
indicators and
display on the
Control Panel are
illuminated.
Press the On/Off
button.
Warewasher not
able to fill.
Ensure the water
supply is turned
fully on.
Ensure the water
supply hose has
not been trapped
or kinked.
Check that the site
water supply has
not been turned
off.
Check that the site
water pressure is
adequate (4.5.1).
Warewasher still
going through fill /
heat cycle.
Check that Fill/Heat
indicator is flashing
amber.
Allow enough time
for the warewasher
to fill and heat
(6.3).
Excessive foam in
Wash Tank.
Wrong type of
wash and/or rinse
aid chemicals.
Check that the
wash and/or rinse
aid chemicals are
commercial ware
washer grade.
Always use the
correct grade of
chemicals.
Wash and/or rinse
aid chemical
injection rate too
high.
Check / adjust the
injection rates of
the wash and rinse
aid chemicals.
Wash Tank not
fully heated.
Check Wash Tank
temperature on
Control Panel
display.
Wrong type of
Prewash
Do not prewash
with soap-based
detergent.
Cycle does not
start.
(Your
warewasher has a
heat interlock
that will delay the
start of the wash
Warewasher not
turned on.
Check that the
indicators and
display on the
Control Panel are
illuminated.
Press the On/Off
button.
cycle until all
cycle start criteria
have been met.
When the criteria
have been met
the heat indicator
will illuminate
green and the
cycle should start.
If this is not the
case, please
check the below
items before
requesting a
service callout.)
Warewasher still
going through fill /
heat cycle.
Check that Fill/Heat
indicator is flashing
amber.
Allow enough time
for the warewasher
to fill and heat
(6.3).
Please refer to the
latest version of the
Engineers Manual
on the Classeq
website for full
information
regarding
temperatures and
interlock settings.
Wash Tank not
full.
Ensure the water
supply is turned
fully on.
Ensure the water
supply hose has
not been trapped
or kinked.
Check that the site
water supply has
not been turned
off.
Check that the site
water pressure is
adequate (4.5.1).
Cycle runs for a
long time.
Rinse water not
hot enough.
Your warewasher
has a heat interlock
to ensure that the
rinse is in
accordance with UK
environmental
health
requirements. This
will extend the
wash cycle if the
Rinse Boiler has
not achieved the
required
temperature
If rinse water is not
hot enough the
Fill/Heat indicator
will be flashing
amber.
Check Rinse Tank
temperature on
Control Panel
display.
Please refer to the
latest version of the
Engineers Manual
on the Classeq
website for full
information
regarding
temperatures and
interlock settings.

Related product manuals