Symptom Cause Solution
Garden hose
connection
leaks.
Loose fittings. Tighten fittings.
Missing/worn rubber washer. Insert new washer. Call the Toll-Free Hotline: 1-866-902-9690
7. Why does the wand/nozzle leak?
Symptom Cause Solution
Spray wand,
extension, or
nozzle leaks.
Spray nozzle not properly attached. Insert the spray nozzle into the trigger gun. Carefully press in
against the spring tension, and twist into thelocked position.
Broken o-ring or plastic insert. Call the Toll-Free Hotline: 1-866-902-9690
8. Why is the pump noisy?
Symptom Cause Solution
Pump is noisy. Pump is sucking air Check that hoses and fittings are airtight. Turn off machine and
purge pump by squeezing trigger gun until a steady flow of water
emerges through the nozzle.
9. Why is there water leaking from the pump?
Symptom Cause Solution
Water leaks from
pump (up to 10 drops
per minute
is permissible).
Loose fittings. Check that all fittings are tight.
Water seals are damaged or worn. Call the Toll-Free Hotline: 1-866-902-9690
10. Why is there oil dripping from my unit?
Symptom Cause Solution
Oil is dripping Oil seals are damaged or worn. Call the Toll-Free Hotline: 1-866-902-9690
11. Why does the motor buzz, but fails to run?
Symptom Cause Solution
Motor buzzes
but fails to run.
Supply voltage below minimum. Verify that only the pressure washer is running on this
circuit.
System has residual pressure. Turn unit "OFF", squeeze trigger on spray wand to release
pressure, then turn unit "ON".
Voltage loss due to extension cord. Unplug any extension cords attached
and plug the unit directly into the outlet.
Pressure washer not used for long periods. Call the Toll-Free Hotline: 1-866-902-9690