Disconnect the machine from the power source before making any repairs.
Symptom Cause Solution
Motor does not run
when “ON”, fully con-
nected and trigger
depressed.
On/Off switch is in the
“OFF” (O) position.
Turn switch to the “ON” ( I
) position.
GFCI is not plugged in. Plug in GFCI.
Extension cord is too long.
Extension cord is not
proper gauge.
Extension cord is dam-
aged.
Replace extension cord
with either a 25’ (7.6 m)
14/3 gauge cord or a 50’
(15 m) 14/3 gauge cord.
Electrical outlet does not
supply adequate power.
Try a different outlet.
Tripped pressure washer
thermal protector.
Allow to cool, and restart
unit.
Unit does not reach high
pressure.
Diameter of garden hose is
too small.
Replace with a 1” (25 mm)
or 5/8” (16 mm) garden
hose.
Water supply is restricted.
Check garden hose for
kinks, leaks and blockage.
Not enough water supply. Open water source fully.
Water inlet lter is clogged.
Remove lter and rinse in
warm water.
Power nozzle is in low-
pressure position.
Replace with desired high-
pressure tip.
Pump is sucking air.
Check that hoses and t-
tings are airtight. Turn
“OFF” machine, and purge
pump by squeezing trigger
gun until a steady ow of
water emerges through the
nozzle.