300 Series
Nitrate / Sulfate
Manual
Installation / Operation Manual
Fully Automatic & Demand
Water Softeners - 2017
300 SERIES

Other manuals for Clearion 300 Series

Questions and Answers

  • K
    kirbykevinAug 17, 2025
    Why is there a loss of water pressure in my Clearion Water Filtration System?
    • Z
      Zachary BoydAug 17, 2025
      A loss of water pressure in your Clearion Water Filtration System can occur due to: * Scaling or fouling of the inlet pipe: Clean or replace the pipeline and consider pretreatment to prevent future issues. * Fouled media: Clean the media and pretreat to prevent recurrence. * Improper backwash setting: Increase the frequency of backwashing.
  • P
    Peter RamirezAug 19, 2025
    What to do if my Clearion Water Filtration System continuously flows to the drain?
    • L
      Lisa PollardAug 19, 2025
      If your Clearion Water Filtration System experiences continuous flow to the drain, it could be due to: * Foreign material in the control valve. * An internal control leak. * The valve being jammed in the backwash, brine, or rapid rinse position. * A stopped or jammed motor. In all of these cases, you should contact your dealer to clean the valve and replace the piston and seals. If the motor is unresponsive, it should also be replaced. Check for jammed piston.
  • L
    Logan SnowAug 22, 2025
    Why does my Clearion Water Filtration System filter fail to regenerate automatically?
    • K
      Kimberly DelacruzAug 23, 2025
      The Clearion Water Filtration System filter might fail to regenerate automatically due to: * The power supply being connected to an intermittent or dead power source: Connect to a constant power source. * Improper control valve programming: Reset the program settings. * A defective power supply: Replace the power supply. * A defective drive motor: Replace the motor.
  • L
    lauren55Aug 25, 2025
    Why is my Clearion Water Filtration System regenerating at the wrong time?
    • A
      Alicia CantuAug 26, 2025
      Regeneration occurring at the wrong time in your Clearion Water Filtration System can be caused by: * The time of day being improperly set, possibly due to a power failure: Reset the time of day programming and install a 9-volt battery. * The regeneration time being set improperly: Reset the regeneration time programming.
  • A
    amywilkersonAug 28, 2025
    How to fix a Clearion 300 Water Dispenser that fails to regenerate automatically?
    • L
      Latoya FitzgeraldAug 28, 2025
      If your Clearion Water Dispenser isn't automatically regenerating, here's what you can check: * Ensure the power supply is connected to a constant power source. * Verify the meter cable is securely reconnected. * Double-check and reset the control valve programming. * Consider replacing the power supply if it's defective. * Clean or replace the meter assembly if it's dirty or defective. * Replace the motor if it's defective.
  • W
    William ParkerAug 30, 2025
    What to do if there is excessive water in the brine tank or salty water from the Clearion 300 Water Dispenser?
    • D
      Deborah BergAug 30, 2025
      If you notice excessive water in the brine tank or salty water coming from your Clearion Water Dispenser, consider the following: 1. Check the drain line for any blockages and ensure proper flow to the drain. Clean the drain line flow control button. 2. Inspect the brine valve for dirt or damage; clean or replace it as necessary. 3. Examine the injector or screen for clogs; clean or replace the injector screen. 4. Ensure the inlet pressure is adequate, with a minimum of 20 psig, to allow the injector to function correctly. 5. Reduce the brine refill time if the refill cycle is too long.
  • A
    Amy PriceSep 2, 2025
    Why is my Clearion 300 Water Dispenser not using salt?
    • M
      Michelle JohnsonSep 2, 2025
      If your Clearion Water Dispenser isn't using salt, try these steps: * Check and reset the control valve programming. * Clean the drain line and/or flow control button if the drain line is plugged or restricted. * Clean or replace the injector and screen if they are plugged. * Check for restrictions in the BLFC, ensure the safety float isn't stuck, and inspect the brine tank for leaks if there's no water in the brine tank. * Ensure the line pressure is at least 20 psi if the water pressure is too low. * Check brine line connections for air leaks if the brine line injects air during brine draw.
  • W
    William IngramSep 5, 2025
    How to restore water pressure in my Clearion 300?
    • S
      stephanie71Sep 5, 2025
      To restore water pressure in your Clearion Water Dispenser: * Clean or replace the pipeline if scaling or fouling of the inlet pipe is present. Consider pretreatment to prevent future issues. * Clean the resin if it's fouled. Also, consider pretreatment to prevent future fouling. * Increase the frequency of backwashing if the backwash setting is improper.
  • E
    Eric KellySep 7, 2025
    How to reduce high salt usage in my Clearion 300 Water Dispenser?
    • D
      darryl64Sep 7, 2025
      To reduce high salt usage in your Clearion Water Dispenser: * Lower the brine tank refill time if the salt setting is too high. * Lower the hardness setting or increase the days between regeneration if it's regenerating too frequently.
  • W
    wallacekellySep 12, 2025
    What causes loss of capacity in a Clearion Water Dispenser?
    • R
      Ronald JohnsonSep 12, 2025
      The causes for loss of capacity in your Clearion Water Dispenser can be: * Increased raw water hardness: Increase the hardness setting or decrease the days between regeneration. * Brine concentration and/or quantity: Keep the brine tank full of salt at all times and clean it yearly. Ensure salt is not bridged. If using a salt grid plate, make sure refill water is over it.

Summary

General Specifications

Nitrate Setup Diagram

Installation Guide: Requirements and Initial Steps

Installation Requirements

Essential criteria and conditions for proper unit installation.

Location and Site Requirements

Guidance on selecting the optimal location and specific site requirements.

Water Supply and Bypass Valve Installation

Step-by-step instructions for connecting the water supply and bypass valve.

Installation Guide: Connections and Pressurization

Drain, Brine, and Electrical Connections

Procedures for connecting drain, brine lines, and electrical supply.

Pressurizing the System

Steps to fill the system with water and remove air.

Regeneration Frequency Calculation

Water Chemistry Conversion

Converts nitrate and sulfate levels to calcium carbonate equivalents.

Ratio Calculation and Capacity

Calculates nitrate/sulfate ratio and determines resin operating capacity.

Installation Guide: System Calculations and Operation

System Capacity and Nitrate Calculation

Calculates system capacity and total nitrate grains for installation.

Control Valve Programming and Operation

Programs valve settings and guides manual regeneration cycles.

Installation Guide: Maintenance and Control

Brine Tank Filling and Final Checks

Instructions for filling the brine tank and performing final installation checks.

Operation, Care, and Cleaning

Guidelines for normal operation, maintenance, and cleaning of the unit.

Regeneration Control

Manual control for initiating or skipping regeneration cycles.

Control Valve Start-Up

Programming the Control Valve

Detailed steps for programming the control valve settings.

Control Valve Start-Up: Menu Navigation

Main Menu Navigation

Guide to navigating the main menu and setting basic parameters.

Control Valve Start-Up: Operation Modes

Normal Operation Modes

Explanation of home display and battery backup features.

Starting Extra Regeneration Cycles

Procedures for initiating delayed or immediate extra regeneration cycles.

Control Valve Start-Up: Advanced Settings

Master Programming Mode Overview

Accessing and modifying advanced programming settings.

Regeneration Settings

Configuring regeneration time, day override, and cycle step durations.

System Capacity and Bluetooth Settings

Configuring system capacity and Bluetooth connectivity settings.

Utilizing Bluetooth Control

Legacy View App Installation

Steps to download and install the Legacy View mobile application.

Connecting to the Valve

Guide to connecting the app to the water treatment valve.

Dashboard Overview

Explanation of the dashboard interface and its informational fields.

Utilizing Bluetooth Control: App Functions

Setting Unit Time via App

Instructions for setting the unit's time using the mobile app.

Setting Backwash Frequency via App

Configuring the frequency of backwash cycles through the app.

Setting Regeneration Time via App

Setting the desired regeneration time using the app interface.

Utilizing Bluetooth Control: Status and Cycles

Status and History View

Viewing and resetting system status and historical data.

Starting Regeneration Cycles via App

Initiating regeneration cycles directly from the app interface.

Powerhead Assembly

Valve Body Assembly

Valve Body Assembly Parts List

Bypass Assembly

Service Instructions: Component Replacement

General Preliminary Instructions

Essential preliminary steps before performing any servicing operations.

Component Replacement Procedures

Step-by-step guides for replacing key valve components and seals.

Service Instructions: Specific Components

Servicing the Injector and Screen

Steps for servicing or replacing the injector and screen.

Replacing the Meter

Instructions for removing, cleaning, or replacing the water meter.

Replacing the Brine Valve

Procedure for replacing the brine valve assembly.

Troubleshooting Guide: Common Issues

Regeneration and Capacity Issues

Diagnosing and correcting regeneration failures and capacity loss.

Water Quality and Pressure Problems

Addressing issues with water quality, salt usage, and water pressure.

Troubleshooting Guide: Salt and Drain Issues

Excessive Brine Tank Water; Salty Water

Troubleshooting excessive brine tank water or salty service water.

Softener Fails to Use Salt

Diagnosing why the softener is not drawing or using salt.

Continuous Flow to Drain

Correcting issues causing continuous water flow to the drain.

Error Codes

Control Valve Error Code Diagnosis

Understanding the error code system and general diagnosis.

Specific Error Code Troubleshooting

Troubleshooting specific control valve error codes and display issues.

Limited Warranty

Warranty Coverage, Terms, and Exclusions

Details on warranty coverage, terms, conditions, and exclusions.

Warranty Limitations, Remedies, and Claims

Understanding warranty limitations, remedies, and the claim process.

Clearion 300 Series Specifications

General IconGeneral
BrandClearion
Model300 Series
CategoryWater Dispenser
LanguageEnglish