5. When wastewater discharge, into a Clearstream Unit, is seasonal or intermittent to a
point that the owner wishes to turn off the electricity (for more than (3) months) to the
aerator, the aerator inlet and outlet should be sealed to keep out moisture until the unit is
ready to be restarted.
CLEARSTREAM INSTALLATION INSTRUCTIONS
Before installation of the Clearstream Treatment Tank, first install a pretreatment
tank (septic tank) with a volume of not less than 50% of the gallon per day rating of the
Clearstream Unit. Pretreatment tanks shall comply with minimum sizing specifications
outlined in the Clearstream specifications section.
UNLOADING/PACKING INSTRUCTIONS:
1. All compressors are packaged to prevent damage during shipping and handling.
2. Please be careful during shipping or handling of the linear or rotary vane compressors
they are fragile and can be damaged if dropped from only a short distance. If dropped
hard enough the cast aluminum housing may be damaged and render the compressor
useless.
3. The most common issue resulting from a linear compressor being handled
inappropriately is the safety switch being tripped. Please refer to the repair manual for
switch reset instructions or safety bolt replacement if needed.
4. The rotary vane compressor is made up of an electrical motor and pump which are
manufactured with very close tolerances. If the pump end is dropped it may cause a
change in those tolerances and damage to vanes or rotor. These damages may not be
able to be repaired thus rendering the compressor useless. If the motor end is dropped it
may damage the external fan and fan guard and may be replaced if damaged. Also, the
bearings in the motor may be damaged if dropped rendering the compressor useless.
5. All control panels are packaged to prevent damage during shipping and handling.
6. Clearstream control panels are fragile and should be handled as such during shipping
and handling. All control panels have circuit breakers, lights and electrical connections
and many have relays and timers that are all fragile. Components may be replaced
if damaged but if the panel enclosure its self is damaged the panel may be rendered
useless.
NCD 1000-1500 SERIES OWNERS MANUAL PAGE 4