Pretreatment Tanks
Minimum Capacity 1/2 Plant Design Flow
Minimum Liquid Depth 30 inches
Four Inch Inlet Tee Baffle Discharge Level 6 inches below liquid level
Four Inch Outlet Tee Baffle Intake Level 25% to 50% of liquid level
Inlet flow line must be a minimum of two inches higher than the outlet flow line.
NCD 1000-1500 SERIES OWNERS MANUAL PAGE 11
SPECIFICATIONS:
Clearstream Units
Model 1000NCD
Treatment Capacity 1000 G.P.D.
BOD Loading 2.5 lbs BOD
Aerator (Dual CS-103ET) 4.8 scfm
Control Panel (Model CS-114A, AP, AT,AN) Raintight
Electrical 120vac/60Hz/1.5A/164 watts
Model 1200NCD
Treatment Capacity 1200 G.P.D.
BOD Loading 3.0 lbs BOD
Aerator (Dual CS-103ET) 5.6 scfm
Control Panel (Model CS-114A, AP, AT, AN) 120vac/60Hz/1.5A/164 watts
Model 1500NCD
Treatment Capacity 1500 G.P.D.
BOD Loading 3.75 lbs BOD
Aerators (CS-103FLL) 7.2 scfm
Control Panel (Model CS-114A, AP, AT, AN) 120vac/60Hz/2.8A/336 watts