10. For below normal grade installations a Clearstream 20-inch diameter riser may be
used. In no case shall more than 18” of maximum riser depth be used on a Clearstream
Unit to bring the access covers above the final grade. All risers must be sealed with
silicone to prevent ground water intrusion before back-fill is completed.
11. Before leaving excavation site, be sure to securely fasten the Clearstream access
covers in place with the tamper resistant bolt(s). Tighten bolts firmly to keep unauthorized
personnel from gaining access to the inside of tank.
CLEARSTREAM AERATOR AND CONTROL PANEL
1. Mount one of the Clearstream Control Panel Model series CS-118 in a location that can
be easily noticed by the occupants.
2. Wire 115 Volt, 60Hz power from an electrical disconnect to Clearstream Control Panel.
Wire from Control Panel to Clearstream Tank electrical junction box through conduit. Use
wiring diagram provided for each version of the Clearstream Control Panel series. All
electrical wiring should be installed by a qualified person in compliance with applicable
section for the National Electrical Code or other more stringent local codes.
3. Install Aerators Model CS-103ET or FLL as close as practical to the tank, but in no case
greater than one hundred (100) feet away. Run 3/4” Sch. 40 PVC air line from aerator
connector to the air line connection at Clearstream tank. Be careful to back-
fill underground air line in manner which will not cause air line to leak. Aerator must be
installed in a location that is dry, non-dusty and highly ventilated.
COMPLIANCE WITH LAWS
The Clearstream Unit must never be installed without first obtaining all permits and
approval from the local regulatory body. In areas that do not have local control over
environmental activities, all applicable State and Federal environmental codes must
be adhered to as well. Only properly licensed and trained individuals should install
Clearstream equipment. The effluent from the system should only be utilized for disposal
as described in NSF/ANSI Standard 40 and as is in compliance with all local, state and
federal requirements. Special care should be taken when installing a unit to prevent cross
connections and protect against backflow to potable water supplies.
START UP PROCEDURES:
INITIAL START UP:
1. Please read all instructions in this owner’s manual prior to use of your Clearstream
Aerobic System. Please call your dealer for specific information concerning your complete
on-site wastewater system. Should you have any questions please call, fax or write
Clearstream Wastewater Systems.