9.6 Window Frame and Latch
9.6.1 The window frame or latch must be replaced
when it becomes difficult to maintain a seal. When
replacing the window frame or latch, the acoustical foam
inside the helmet should also be replaced.
9.7 Chin Strap
9.7.1 Replace the chin strap when worn or when it
loses its elasticity.
9.8 Air-Inlet Fitting
9.8.1 Use a wrench to remove the old fitting.
9.8.2 Apply a drop of cyanoacrylate (super glue) to
one end of the new fitting, and screw the glued end
hand-tight into the helmet.
9.8.3 Connect the breathing tube and use the tube for
leverage to tighten the inlet fitting. Do not use a wrench
to tighten the fitting, as it may damage the helmet. Leave
the breathing tube connected until the cyanoacrylate has
set.
9.9 Removing and Replacing the Air Baffle
Partition
9.9.1 Remove the cape and suspension per Sections
9.3 and 9.4.
9.9.2 Pull the partition to remove it from the helmet.
9.9.3 Place a new partition into the helmet, with the
break to the back and pointing toward the inlet fitting.
When the partition is positioned correctly, the break
should point down at a slight angle, gradually tapering
toward the helmet shell.
9.9.4 Align the partition’s center notches with the
retaining bosses. Apply pressure on the partition to snap
it into the bosses. Working from the center, snap the
partition in place toward the front and back.
9.9.5 Replace the suspension and cape.
10.0 REPLACEMENT PARTS
WARNING
Use of any non-Clemco replacements parts may
permit ingress of hazardous contaminants, and
may cause injury, disease, or death to the user.
OSHA Regulation 29 CFR 1910.134(H)(4)(i)
requires the use of the respirator
manufacturer’s NIOSH-approved parts
designated for the respirator. Using any parts
listed in this section made by any manufacturer
other than Clemco voids the NIOSH approval,
and voids Clemco’s warranty.
10.1 Apollo 600 HP Supplied-Air Respirator
Systems with Web Suspension
and Alternate
Accessories
Apollo 600 HP Less Respirator Hose, with:
Description Stock No.
CFC constant-flow connector ................. 24001
ACV air-control valve ............................. 24002
CAT cool-air tube ................................... 24003
CCT climate control tube ....................... 24004
Clem-Cool air conditioner ...................... 24932
With 50 ft Respirator Hose, and:
Description Stock No.
CFC constant-flow connector ................. 24771
ACV air-control valve ............................. 24210
CAT cool-air tube ................................... 24211
CCT climate control tube ....................... 24212
Clem-Cool air conditioner ...................... 24933
With 50 ft Respirator Hose, CPF-20 Filter and:
Description Stock No.
CFC constant-flow connector ................. 24772
ACV air-control valve ............................. 24213
CAT cool-air tube ................................... 24214
CCT climate control tube ....................... 24215
Clem-Cool air conditioner ...................... 25299

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clemco 600 and is the answer not in the manual?

Clemco 600 Specifications

General IconGeneral
BrandClemco
Model600
CategoryRespiratory Product
LanguageEnglish