CLEANING
Warning! Before cleaning the product, make sure it has cooled down and that the plug is not inserted into the socket.
1. Clean the pot after each use.
2. Remove the lid and remove the inner pot. Clean it with water and a non-abrasive detergent that could ruin the
surface of the product.
3. Use water and a soft cloth to clean the lid, including the gasket which is easily removable.
4. Clean the pot body with a damp cloth. DO NOT immerse the pot in water. Do not use a wet cloth to clean the pot
while the power cord is connected to the power outlet.
PRODUCT FAULTS AND ELIMINATION METHODS
37
36
Number Function Default
time (min)
Cooking
standard
Adjustable
time
Default
pressure
Adjustable pressure
Postpone switch on
(you can set pushing
delay start”)
0:30-24:00
NO DESCRIPTION CAUSE SOLUTION
1 Unable to close lid. The installation of gasket is not
correct.
Calibrate the position of the
gasket.
/ / / /
11
Yogurt
8H
20-30-40
You can
adjust the
time keep
pushing
“yogurt
30min-24H
Pushing
delay start
botton to
postone
30 min
/// / / /12
Pressure
cook
/// / / /13
Cancel
/// / / /14
Pressure
level
/// / / /16
Keep
Warm
/30min / /15
Delay
Start
The ball oat valve on splint is
jammed.
Gently poke the valve plate.
2 Unable to open lid. The ball oat valve doesn’t fall. Use a toothpick to gently
poke the valve.
3 The air leakage of
pot cover.
The installation of gasket is not
correct.
Calibrate the position of the
gasket.
4 The air leakage of
the ball oat valve.
The gasket of the ball oat valve
has stains.
Clean the gasket of ball
oat valve.
5 The ball oat valve
is not rising.
Water and food don’t reach the
minimum limit.
According to instructions,
use the correct amount of
water and food.
6 E1 Open circuit of the sensor.
Send the electric pressure cooker
to the maintenance center to check.
Send the electric pressure cooker
to the maintenance center to check.
Send the electric pressure cooker
to the maintenance center to check.
Send the electric pressure cooker
to the maintenance center to check.
7 E2 Short circuit of the sensor.
8 E3 Overheating
9 E4 Low temperature
Air leakage of pot cover or
discharge pressure valve.
Send the electric pressure
cooker to the maintenance
center to check.
The gasket of the ball oat valve
is damaged.
Replace the gasket of ball
oat valve.
Gasket has stains. Clean the gasket.
The cover is not sealed.
Cover the lid according to
the manual.
Gasket is damaged. Replace the gasket.