General (continued)
Amplifier Protection
Overcurrent
DC
Thermal monitoring
Switch-on delay
Status Indicators Power applied, Protection active, Signal peak, and Signal present
Cooling Variable speed fan
Dimensions
(W x H x D)
Net 482.6 mm x 88 mm x 381.8 mm (19 in x 3.46 in x 15.03 in)
Shipping 606 mm x 164 mm x 558 mm (23.9 in x 6.5 in x 22 in)
Weight
CV2500 CV4250 CV8125
Net 6.86 kg
(15.37 lb)
7.26 kg
(16.26 lb)
8.05 kg
(18.03 lb)
Shipping 8.86 kg
(19.85 lb)
9.26 kg
(20.74 lb)
10.05 kg
(22.51 lb)
1. Odd- and even-numbered channel groups can deliver up to 500 W simultaneously, but in models with more than two channels, the
available power is reduced proportionately when any channel is delivering more than its nominal rating.
Notes re Power Consumption and Heat Loss measurements: All measurements at 230 VAC 50 Hz power input
2. Standby: amplifier in standby state
3. Idle: amplifier not in standby state, but no audio output
4. 1/8th Power: constant sound level at 1/8 of the rated output power (audio mainly clean, only occasional clipping)
5. 1/3rd Power: constant sound level at 1/3 of the rated output power (audio beginning to become compressed, limited or heavily clipped)
Energy Star certificate web link: http://www.ul.com/customer-resources/ul-energy-efficient-product-database/
UL Energy Efficient Product Database.
Technical Specifications (continued)