TROUBLESHOOTING GUIDE
Problem/Symptom Possible Causes on
Low output voltage Overload Reduce the load.
No output voltage Low input voltage
Recharge ba!ery. Check
connec"ons and cable.
No output voltage
a#er prolonged use
Thermal shutdown Allow inverter to
cool o.
Reduce load, con"nuous
opera"on input current
required.
Improve ven"la"on;
make sure ven"la"on
openings in the inverter
are not obstructed.
Reduce ambient
temperature.
No output voltage,
“Protect” indicator
lighted
High input voltage Make sure the inverter
is connected to 12V
ba!ery.
Check regula"on or
charging system.
No output voltage Short circuit
Check load for proper
opera"on.
No output voltage Inverter switched off
No power to inverter
Reverse DC polarity
Turn inverter on.
Check wiring to inverter.
Observe correct
polarity.
Low ba!ery alarm on
all the "me
Poor DC wiring
Poor ba!ery
condi"on
Check connec"ons.
Make sure ba!ery is
fully charged.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cobra PRO Series and is the answer not in the manual?

Cobra PRO Series Specifications

General IconGeneral
Input Voltage12V DC
Output Voltage120V AC
Output WaveformModified Sine Wave
Frequency60 Hz
ModelPRO Series
Continuous Power1500W
Peak Power3000W
AC Outlets2
CoolingFan
Protection FeaturesOverload, Short Circuit
DimensionsVaries by model
WeightVaries by model