EasyManuals Logo

Cointra CPA Series User Manual

Cointra CPA Series
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
cod. 3541S050 - Rev. 01 - 07/201919
EN
CPA
Trademark: COINTRA
Type: Conventional water heater
Item
Symbol
Unit
Value
CPA 6
GCA1HKKF
CPA 11
GCL1MKKA
CPA 14
GCI1PKKF
Declared load profile
XS
M
M
Water heating energy efficiency
class (from A+ to F)
A
A
A
Daily electricity consumption
Qelec
kWh
0,000
0,000
0,000
Annual electricity consumption
AEC
kWh
0
0
0
Water heating energy efficiency
NWh
%
58
76
74
Daily fuel consumption
Qfuel
kWh
2,874
8,185
8,562
Annual fuel consumption
AFC
GJ
2
6
6
Thermostat temperature settings of the water
heater, as placed on the market
MAX
MAX
MAX
Sound power level
LWA
dB
57
58
59
Emissions of nitrogen oxides
NOx
mg/kWh
52
37
42
ErP product fiche (Models LPG)
Trademark: COINTRA
Type: Conventional water heater
Item
Symbol
Unit
Valore
CPA 6
GCA1HLKF
CPA 11
GCL1MLKA
CPA 14
GCI1PLKF
Declared load profile
XS
M
M
Water heating energy efficiency
class (from A+ to F)
A
A
A
Daily electricity consumption
Qelec
kWh
0,000
0,000
0,000
Annual electricity consumption
AEC
kWh
0
0
0
Water heating energy efficiency
NWh
%
58
76
74
Daily fuel consumption
Qfuel
kWh
2,874
8,185
8,562
Annual fuel consumption
AFC
GJ
2
6
6
Thermostat temperature settings of the water
heater, as placed on the market
MAX
MAX
MAX
Sound power level
LWA
dB
57
58
59
Emissions of nitrogen oxides
NOx
mg/kWh
37
58
62

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cointra CPA Series and is the answer not in the manual?

Cointra CPA Series Specifications

General IconGeneral
Fuel TypeNatural Gas or LPG
IgnitionElectronic ignition
Gas Connection1/2"
Water Connection1/2"
Safety FeaturesFlame failure device, overheat protection
MountingWall-mounted