EasyManua.ls Logo

Cointra CPA - Technical Data Table

Cointra CPA
72 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
EN
CPA
Rev. 00 - 11/2018
4.4 Technical data table
Data Units 11 14
Product identication codes G20
GCL1MKKA GCI1PKKF
Product identication codes G31
GCL1MLKA GCI1PLKF
Countries of destination IT - ES - PT - FR - GB - BE
Gas category
II2HM3P (IT) - II2H3+ (ES - PT - GB)
II2E+3+ (FR) - I2E+ (BE) - I3+ (BE)
Maximum heat capacity kW 21.1 26.8 Q
Minimum heat capacity kW 8.1 10.7 Q
Maximum heat capacity kW 18.9 23.8
Minimum heat capacity kW 7.0 9.3
Performance at max. power % 88.5 88.7
Burner injectors G20 no. x Ø 12 x 0.85 14 x 0.85
Gas supply pressure G20 mbar 20 20
Maximum gas delivery G20 m
3
/h 2.23 2.84
Minimum gas delivery G20 m
3
/h 0.86 1.13
Burner injectors G31 no. x Ø 12 x 0.50 14 x 0.50
Gas supply pressure G31 mbar 37 37
Max. gas delivery G31 m
3
/h 1.64 2.08
Min. gas delivery G31 m
3
/h 0.63 0.83
NOx emission class - 6 (<56 mg/kWh) NOx
Max. operating pressure bar 10 10 MSP
Min. operating pressure bar 0.2 0.2
DHW delivery ∆25º l/min 11 13.7
DHW delivery ∆30º l/min 5.5 6.9
Degree of protection IP X4D X4D
Supply voltage V/Hz 230 V/50 Hz
Absorbed electrical power W / /
Empty weight Kg 9.50 13.50
Type of unit B11BS

Table of Contents