OPERATION MANUAL CMVeco 125 - 400
Plastic industrial fan
Agent :
Order No .:
Fan type :
Year of manufacture :
For use in Ex zones
Not for use in Ex zones
COLASIT AG
Faulenbachweg 63
CH-3700 Spiez
Tel.: +41 (0)33 655 61 61
Fax: +41 (0)33 654 81 61
info@colasit.ch
www.colasit.ch

Table of Contents

Questions and Answers

  • P
    Peter LangAug 12, 2025
    Why is the Colasit Fan output too low?
    • T
      Tonya AllenAug 12, 2025
      If the Colasit Fan output is too low, it might be due to a few reasons. First, check the impeller's rotation direction and change it if it's incorrect. High pressure losses in the ducts could also be the cause, consider changing the duct arrangement. Finally, make sure the restrictors are fully open.
  • J
    Jim WilsonAug 16, 2025
    What to do if V-belts slip on Colasit Fan?
    • C
      Christy BrownAug 16, 2025
      If the V-belts on your Colasit Fan are slipping, it could be due to incorrect pretension. Check the belt tension and retighten if necessary. Another cause could be foreign bodies or soiling in the grooves or pulleys, so clean the pulleys and check the belt profile.
  • D
    Donna LandryAug 19, 2025
    How to fix a Colasit Fan that is not running smoothly?
    • R
      Raymond CampbellAug 20, 2025
      If your Colasit Fan is not running smoothly, several factors could be at play. The impeller might be imbalanced, requiring rebalancing by a specialist company. Alternatively, the impeller could be caked up, requiring careful cleaning and rebalancing if necessary. Material corrosion or deformation due to high temperature may also be the cause, in which case you should consult the manufacturer and check bearings. Also, ensure the V-belt drive is correctly aligned, and adjust the belt drive if needed.
  • H
    Heather AndersonAug 23, 2025
    What causes a Colasit CMVeco 160 to fail to reach its rated speed?
    • C
      cooperjonathanAug 23, 2025
      If the Colasit Fan fails to reach its rated speed, it could be due to incorrectly adjusted electrical switching mechanisms; check the motor protection setting and reset if necessary. Also, the motor winding might be defective, or the drive motor drive not correctly designed, please consult manufacturer to verify starting torque.
  • Q
    qhernandezAug 27, 2025
    Why is there a rise in temperature of roller bearings in my Colasit CMVeco 160 Fan?
    • E
      Eric JonesAug 27, 2025
      A rise in temperature of roller bearings in Colasit Fan can happen if the bearing was not greased. To solve this, change the bearing and grease at regular intervals as stipulated in the maintenance instructions.
  • N
    Nichole MartinAug 31, 2025
    What causes a V-belt to be torn or damaged on a Colasit Fan?
    • M
      Mark WebsterAug 31, 2025
      If the V-belt on your Colasit Fan is torn or damaged, it might be due to normal wear and tear, in which case you should replace V-belts in sets. Alternatively, the V-belt might be pretensioned too strongly, so tension replacement belt to manufacturer’s specifications.
  • D
    Donald MorrisSep 3, 2025
    What to do if there is a leak on sleeves of Colasit CMVeco 160?
    • C
      Christina FisherSep 4, 2025
      If you notice a leak on the sleeves of your Colasit Fan, it could be because the sleeves are defective; replace them. Alternatively, the tensioning straps might not be tight enough, so retighten them.
  • M
    Monique Stevenson MDSep 7, 2025
    Why is my Colasit CMVeco 160 making grinding noises when running or starting?
    • K
      kathryn69Sep 7, 2025
      Grinding noises when your Colasit Fan is running or starting can occur if the intake duct is fitted under tension. To resolve this, remove the intake duct and realign it.

Summary

Part 1: General

1 General

General information about the COLASIT fan, including definitions, warranty, and safety.

1.4 Safety review

Recommends operator review of the operational environment after installation.

1.5 Personnel qualifications

States only trained and authorized personnel may operate, handle, and maintain the fan.

1.6 Possible emergencies

Describes potential emergencies like component bursting, melting, or fire.

1.8 General risk matrix

Lists various risks and safety precautions related to operation and maintenance.

1.10 Restrictions when commissioning

Outlines mandatory steps before commissioning, including reading manual and safety inspector approval.

2 Explosion protection

4 Installation, configuration

5 Commissioning, initial startup, test run

6 Operation

6.1 Safety instructions

States the fan must be operated according to the manual to avoid damage.

7 Maintenance, repair, cleaning

9 Operating instructions

12 Troubleshooting

Part 2: Units

17 Assembly instructions

Part 3: Certification

19.2 ATEX-Declaration of Conformity

Presents the ATEX declaration of conformity and applicable harmonised standards.

20 Form for the correct assembly ATEX-fans

Colasit CMVeco 160 Specifications

General IconGeneral
BrandColasit
ModelCMVeco 160
CategoryFan
LanguageEnglish