COLASIT AG
Plastic construction
CH-3700 Spiez
Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61
TD-000 674-E
Edition 4/2016, Subject to alteration
Copyright by COLASIT AG Spiez
Page 1
OPERATION MANUAL CMVeco 125 - 400
Plastic industrial fan
Agent :
Order No .:
Fan type :
Year of manufacture :
For use in Ex zones
Not for use in Ex zones
COLASIT AG
Faulenbachweg 63
CH-3700 Spiez
Tel.: +41 (0)33 655 61 61
Fax: +41 (0)33 654 81 61
info@colasit.ch
www.colasit.ch

Table of Contents

Questions and Answers

  • A
    Andrew LynchAug 13, 2025
    Why is the Colasit CMVeco 250 Fan output too low?
    • D
      Deborah BlairAug 13, 2025
      If the Colasit Fan output is too low, it might be due to a few reasons. First, check the impeller's rotation direction and change it if it's incorrect. High pressure losses in the ducts could also be the cause, consider changing the duct arrangement. Finally, make sure the restrictors are fully open.
  • M
    myerschristopherAug 17, 2025
    What to do if V-belts slip on Colasit CMVeco 250?
    • B
      Billy HodgesAug 17, 2025
      If the V-belts on your Colasit Fan are slipping, it could be due to incorrect pretension. Check the belt tension and retighten if necessary. Another cause could be foreign bodies or soiling in the grooves or pulleys, so clean the pulleys and check the belt profile.
  • K
    Karen WilliamsAug 21, 2025
    How to fix a Colasit CMVeco 250 Fan that is not running smoothly?
    • M
      Manuel Wang Jr.Aug 21, 2025
      If your Colasit Fan is not running smoothly, several factors could be at play. The impeller might be imbalanced, requiring rebalancing by a specialist company. Alternatively, the impeller could be caked up, requiring careful cleaning and rebalancing if necessary. Material corrosion or deformation due to high temperature may also be the cause, in which case you should consult the manufacturer and check bearings. Also, ensure the V-belt drive is correctly aligned, and adjust the belt drive if needed.
  • B
    bobbysanchezAug 25, 2025
    What causes a Colasit CMVeco 250 Fan to fail to reach its rated speed?
    • H
      Hannah DonovanAug 26, 2025
      If the Colasit Fan fails to reach its rated speed, it could be due to incorrectly adjusted electrical switching mechanisms; check the motor protection setting and reset if necessary. Also, the motor winding might be defective, or the drive motor drive not correctly designed, please consult manufacturer to verify starting torque.
  • E
    Erin LopezAug 28, 2025
    Why is there a rise in temperature of roller bearings in my Colasit CMVeco 250?
    • B
      brandon15Aug 28, 2025
      A rise in temperature of roller bearings in Colasit Fan can happen if the bearing was not greased. To solve this, change the bearing and grease at regular intervals as stipulated in the maintenance instructions.
  • M
    Mike MarksSep 1, 2025
    What causes a V-belt to be torn or damaged on a Colasit Fan?
    • S
      Sandra LeSep 2, 2025
      If the V-belt on your Colasit Fan is torn or damaged, it might be due to normal wear and tear, in which case you should replace V-belts in sets. Alternatively, the V-belt might be pretensioned too strongly, so tension replacement belt to manufacturer’s specifications.
  • A
    Ann MendozaSep 5, 2025
    What to do if there is a leak on sleeves of Colasit CMVeco 250?
    • J
      jerrywhiteSep 5, 2025
      If you notice a leak on the sleeves of your Colasit Fan, it could be because the sleeves are defective; replace them. Alternatively, the tensioning straps might not be tight enough, so retighten them.
  • M
    martinmorganSep 9, 2025
    Why is my Colasit Fan making grinding noises when running or starting?
    • P
      Penny WattsSep 9, 2025
      Grinding noises when your Colasit Fan is running or starting can occur if the intake duct is fitted under tension. To resolve this, remove the intake duct and realign it.

Summary

Part 1: General

2 Explosion protection

Details safety measures and requirements for operating fans in potentially explosive atmospheres.

6 Operation

Instructions and safety guidelines for the correct operation of the fan.

7 Maintenance, repair, cleaning

Procedures for routine maintenance, repair, and cleaning of the fan.

12 Troubleshooting

A guide to identifying and resolving common faults and issues with the fan.

Part 2: Units

17 Assembly instructions

Step-by-step instructions for assembling the CMVeco fans.

Part 3: Certification

19.2 ATEX-Declaration of Conformity

Declaration of Conformity specifically for ATEX compliance, detailing standards and marking.

Colasit CMVeco 250 Specifications

General IconGeneral
BrandColasit
ModelCMVeco 250
CategoryFan
LanguageEnglish