APPENDIX B:
RESIDUAL RISKS
When safety instructions are followed, most of the risks associated with the Aero 40FP are mitigated.
However, the operator should be aware that a few residual risks remain.
1. Carbon Dioxide
CO
2
is an asphyxiant gas, which displaces the oxygen in the air. When the carbon dioxide levels
are not monitored, there is a risk of exposure to high concentrations of CO
2
. Exposure to high
concentrations of carbon dioxide can result in shortness of breath, headaches, dizziness, increased
heart rate, impaired hearing, nausea, loss of consciousness or, in extreme cases, death. Always use a
CO
2
PRQLWRULQJGHYLFHZKHQXVLQJWKH$HUR)3LQDFRQȴQHGVSDFH
Solid CO
2
is extremely cold (-109 °F/-78 °C). This presents a risk to the operator, as direct contact with
skin or eyes quickly causes tissue damage. Always protect skin from direct contact with CO
2
pellets,
nuggets or slices.
2. Noise Emissions
When the proper safety precautions are not followed, prolonged exposure to the noise emitted by
the Aero 40FP can cause damage. Long-term exposure to loud noises can result in loss of hearing or
tinnitus. Always wear ear protection.
3. Pressurized Air
Operating the Aero 40FP requires the use of pressurized air, resulting in the risk of hoses bursting or
ȴWWLQJVIDLOLQJ$OZD\VEHDOHUWZKHQRSHUDWLQJWKHPDFKLQHU\ΖIDIDLOXUHGRHVRFFXUEHVXUHWRWXUQ
RWKHDLUDWWKHVRXUFH
Never hold the air stream directly against skin. This could result in an air embolism, which is often fatal.
4. Static Electricity
Static electricity can interfere with the proper functioning of a pacemaker.
Even when grounding or bonding procedures are followed, static electricity can present a danger to
the operator. To reduce this risk, always follow grounding or bonding instructions.