8.Readout
This thermostat can read the amount of time (in percent) that the heating has been turned on within
a certain period.
9.Factory Reset
Setting parameters
No. Name Default parameter Setting range
1 Time / /
2 °F/°C °F
°F
°C
3 Sensor Type 00 3950
00 3950
01 3600
02 3700
4 Sensor Selection Floor
Room
Floor
Room.Limit
5 Calibration 0°C -5°C -- 5°C
6 Location Home
Home
Office
7 Adaptive No
Yes
No
8 Readout / /
9 Factory Reset
N
o
No
Yes
Troubleshooting
E1: Built-in probe failure, please contact your dealer or professional technician.
E2: External probe failure, please contact your dealer or professional technician.
Dimension (mm)
Readout setting:
Enter settings. Press
▲or▼button to Readout.
Press OK button to get.
Press▲or▼button to get 1Day, 30Days and 365Days.
Press OK button to come back to setting interface.
Factory Reset setting:
Enter settings. Press▲or▼button to Factory Reset.
Press OK button to get.
Press▲or▼button to get Yes or NO.
Press OK button to confirm.
Press OK button to come back to Active display interface.