Display DY2 reads ---”.
3. Press button to select a time-based cycle.
4. Use buttons and to set the desired cycle time.
5. Press button to start the soft blast chilling cycle.
The led button comes on.
The compressor only starts working 5 seconds after key is pressed (pump-down 6.4).
DY1 gives room probe temperature, DY2 the cycle time remaining.
If you press button while the cycle is running, you can view the time elapsed since it started.
6. A buzzer sounds to advise that the blast chilling cycle has finished.
7. At the end of the cycle, holding mode starts and continues indefinitely at a holding temperature of +3°C.
The led button flashes.
If you press button during holding time, you can view the time of the cycle just completed to see how long
it took.
The holding stage must last only as long as strictly necessary.
8. To exit holding mode, press button .
The led button goes off.
The compressor stops 5 seconds after button is pressed (pump-down 6.4).
Important
When a soft blast chilling cycle is started, the compressor works non-stop until air temperature in the
compartment reaches -2°C. After this, it can cycle on and off to keep this temperature constant and prevent
frost from forming.
The blast chilling cycle ends when the timer completes the countdown.
8.2 TIME -BASED HARD BLAST CHILLING
The time-based hard blast chilling cycle is controlled by the timer.
Shortcut commands while in standby mode
1
Hard blast chilling 2
Time-based cycle
3
Start
Français
Русский
Detailed commands sequence:
1. Make sure the appliance is in standby mode (6.1).
2. Press button to select the hard blast chilling cycle.
The led button comes on.
Display DY1 gives the setpoint of the air in the compartment (-35°C).
Display DY2 reads ---”.
3. Press button to select a time-based cycle.
4. Use buttons and to set the desired cycle time.
5. Press button to start the hard blast chilling cycle.
The led button comes on.
The compressor only starts working 5 seconds after key is pressed (pump-down 6.4).
DY1 gives room probe temperature, DY2 the cycle time remaining.
If you press button while the cycle is running, you can view the time elapsed since it started.
6. A buzzer sounds to advise that the blast chilling cycle has finished.
7. At the end of the cycle, holding mode starts and continues indefinitely at a holding temperature of +3°C.
The led button flashes.
32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the coldline W10T and is the answer not in the manual?

coldline W10T Specifications

General IconGeneral
Brandcoldline
ModelW10T
CategoryFreezer
LanguageEnglish

Related product manuals