If you press button during holding time, you can view the time of the cycle just completed to see how long
it took.
The holding stage must last only as long as strictly necessary.
8. To exit holding mode, press button .
The led button goes off.
The compressor stops 5 seconds after button is pressed (pump-down 6.4).
Important
When a hard blast chilling cycle is started, the compressor works non-stop until air temperature in the
compartment reaches -35°C. After this, it can cycle on and off to keep a constant temperature of -2°C, preventing
the formation of frost.
The blast chilling cycle ends when the timer completes the countdown.
8.3 TIME -BASED BLAST FREEZING
The time-based blast freezing cycle is controlled by the timer.
Shortcut commands while in standby mode
1
Blast freezing
2
Time-based cycle3
Start
Italiano
English
Detailed commands sequence:
1. Make sure the appliance is in standby mode (6.1).
2. Press button to select the blast freezing cycle.
The led button comes on.
Display DY1 gives the setpoint of the air in the compartment (-38°C).
Display DY2 reads ---”.
3. Press button to select a time-based cycle.
4. Use buttons and to set the desired cycle time.
5. Press button to start the blast freezing cycle.
The led button comes on.
The compressor only starts working 5 seconds after key is pressed (pump-down 6.4).
DY1 gives room probe temperature, DY2 the cycle time remaining.
If you press button while the cycle is running, you can view the time elapsed since it started.
6. A buzzer sounds to advise that the blast chilling cycle has finished.
7. At the end of the cycle, holding mode starts and continues indefinitely at a holding temperature of -20°C.
The led button flashes.
If you press button during holding time, you can view the time of the cycle just completed to see how long
it took.
The holding stage must last only as long as strictly necessary.
8. To exit holding mode, press button .
The led button goes off.
The compressor stops 5 seconds after button is pressed (pump-down 6.4).
Important
When a blast freezing cycle is started, the compressor works non-stop until air temperature in the
compartment reaches -38°C. After this, it can cycle on and off to keep this temperature constant.
The blast freezing cycle ends when the timer completes the countdown.
33
Deutsch
Français
Русский
Question and Answer IconNeed help?

Do you have a question about the coldline W10T and is the answer not in the manual?

coldline W10T Specifications

General IconGeneral
ModelW10T
TypeWorktop Freezer
Weight205 lbs
Energy Star CertifiedNo
Defrost TypeManual
Dimensions (H x W x D)85 cm x 60 cm x 65 cm

Summary

INSTALLATION

Putting into operation

Covers pre-operation checks, power supply, and earthing requirements.

DESCRIPTION OF CYCLES

Notions on blast chilling/blast freezing cycles

Explains the basic principles and types of blast chilling/freezing cycles.

OPERATION

Switching on/off

Instructions for powering the appliance on and off.

TEMPERATURE-BASED BLAST CHILLING/BLAST FREEZING

Temperature-based soft blast chilling

Details the procedure for soft blast chilling using temperature control.

Temperature -based hard blast chilling

Details the procedure for hard blast chilling using temperature control.

Temperature -based blast freezing

Details the procedure for blast freezing using temperature control.

TIME-BASED BLAST CHILLING/BLAST FREEZING

Time-based soft blast chilling

Details the procedure for soft blast chilling using timed control.

Time-based hard blast chilling

Details the procedure for hard blast chilling using timed control.

Time-based blast freezing

Details the procedure for blast freezing using timed control.

PROGRAMS

ALARMS

MAINTENANCE AND CLEANING

Related product manuals