EasyManua.ls Logo

Coleman Dual Fuel - User Manual

Coleman Dual Fuel
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
4010003804 (20080724)
The Coleman Company, Inc. • 3600 North Hydraulic • Wichita, KS 67219 U.S.A.
1-800-835-3278 • TDD: 316-832-8707
Sunbeam Corporation (Canada) Limited • DBA Jarden Consumer Solutions
20B Hereford Street
Brampton, ON L6Y 0M1 • 1 800 387-6161
© 2008 The Coleman Company, Inc. All rights reserved. Coleman
®
, and
are registered trademarks and Dual Fuel™ is a trademark of The Coleman Company, Inc.
© 2008 The Coleman Company, Inc. Tous droits réservés. Coleman
®
, et
sont des marques déposées
alors que
Dual Fuel™
est une marque de commerce de
The Coleman Company, Inc.
© 2008 The Coleman Company, Inc. Todos los derechos reservados. Coleman
®
, y
son marcas registradas
y
Dual Fuel™
es una marca de la compañía
The Coleman Company, Inc.
www.coleman.com
Dual Fuel
TM
Stoves
Instructions for use
© 2008 The Coleman Company, Inc.
www.coleman.com
Dual Fuel
Stoves
English
®
IMPORTANT
CONSUMER/USER: This instruction manual
contains important information necessary for the
proper assembly and safe use of the appliance.
Read and follow all warnings and instructions before
assembling and using the appliance. Follow all
warnings and instructions when using the appliance.
Keep this manual for future reference.
If you have questions about assembly, operation, servicing or repair of this
appliance, please call Coleman at 1-800-835-3278 or TDD: 316-832-8707. In
Canada call 1-800-387-6161.
428, 424, 414 Standard Ignition
414, 424 Electronic Ignition

Questions and Answers

  • H
    hannah07Jul 27, 2025
    How to fix low heat on a Coleman Dual Fuel?
    • H
      Hector CarterJul 27, 2025
      If your Coleman Stove is producing low heat, the generator tip might be clogged. Try moving the LIGHTING LEVER up and down several times to clean it. Also, make sure you are using only fresh and clean fuel.
  • R
    Robert ParkerAug 2, 2025
    What to do if the Coleman Stove pump does not pressurize?
    • O
      Omar JuarezAug 2, 2025
      If the pump on your Coleman liquid fuel canister isn't building pressure, the pump seals might be dry or worn. Try squirting a few drops of oil into the OIL HOLE in the pump cap. If that doesn't solve the problem, you might need to replace the pump seals or get a new pump assembly.
  • S
    Sara WilsonAug 8, 2025
    How to fix intermittent yellow flame on Coleman Dual Fuel?
    • L
      Lee BoydAug 8, 2025
      If your Coleman Stove shows an intermittent yellow flame after using it for a while on a low heat setting, adjust the flame to a slightly higher level using the FUEL VALVE.
  • L
    Lee SilvaAug 13, 2025
    What causes a persistent small yellow flame on a Coleman Dual Fuel Stove?
    • C
      Carol JimenezAug 13, 2025
      If your Coleman Stove has a persistent small yellow flame, the generator might be faulty and needs replacement.
  • N
    Nicolas Mendoza Jr.Aug 19, 2025
    Why does my Coleman Stove have a yellow smokey flame?
    • B
      blopezAug 19, 2025
      If the Coleman Stove burner produces a yellow, smokey flame, it might be due to obstructions like spider webs or insects in the burner and air tube. Remove the burner to inspect and clean these components.

Summary

Safety Precautions and Hazards

Carbon Monoxide Hazard

Appliance produces odorless carbon monoxide. Use only in well-ventilated areas to avoid death.

Critical Warnings and Hazards

Explosion and Fire Hazards

Product can be a source of ignition. Never use in spaces with combustibles. Maintain clearances.

Carbon Monoxide Dangers

Stove produces CO. Symptoms include flu-like effects. Get fresh air if symptoms appear.

Technical Information and Setup

Filling the Fuel Tank

Procedures for safely filling the fuel tank outdoors, closing valves and pump knob.

Operating Procedures

Leak Check

Instructions on how to check for fuel leaks using visual, auditory, or olfactory methods.

Installation and Lighting

Lighting the Main Burner

Instructions for lighting standard and electronic ignition stoves, with safety warnings.

Storage and Auxiliary Burner Operation

Troubleshooting and Leak Checks

Troubleshooting Common Issues

Addresses issues like burner not lighting, low heat, yellow flame, and pump problems with solutions.

Coleman Dual Fuel Specifications

General IconGeneral
Burners2
Wind ProtectionWindBlock panels
IgnitionMatch light
Weight11.8 lbs
MaterialSteel
Fuel TypeUnleaded gasoline or Coleman Liquid Fuel
Burn TimeUp to 2 hours on high
BTU14, 000 total BTUs