95.5% AFUE SINGLE STAGE
GAS-FIRED MANUFACTURED HOUSING
MULTI-POSITION GAS FURNACES
MODELS: MG9S
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement,
specifications are subject to change without notice.
Additional efficiency rating information can
be found at www.gamanet.org.
TECHNICAL
GUIDE
TECHNICAL
GUIDE
426499-BTG-C-0912
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow applications and may be converted for downflow appli-
cations.
These furnaces are designed for residential mobile home, man-
ufactured, or modular home installation. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV direct vent, sealed combustion
listed and may be vented either through side wall or roof appli-
cations using approved plastic combustion air and vent piping.
WARRANTY
15-year limited warranty on the heat exchanger.
2-year limited parts warranty.
FEATURES
Easily applied in upflow or downflow installation with minimal
conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
Low unit amp requirement for easy replacement application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with increased
dependability and reliability.
100% shut off main gas valve for extra safety.
4 speed, direct drive PSC motor.
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary heat exchanger made of corrosion resistant
stainless steel materials.
Timed on, adjustable off blower capability for maximum
comfort.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow at
ductblaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Protection included from air intake, exhaust vent, or
condensate blockage.
Patent pending self priming internal condensate trap design
for easy installation.
Venting applications - installed as a 2-pipe (sealed
combustion) using outdoor air for combustion.
No special vent termination required.
1/4 turn knobs provided for easy door removal.
Question and Answer IconNeed help?

Do you have a question about the Coleman MG9S060B12MP11 and is the answer not in the manual?

Coleman MG9S060B12MP11 Specifications

General IconGeneral
BrandColeman
ModelMG9S060B12MP11
CategoryFurnace
LanguageEnglish

Summary

Product Description and Features

Product Description

Overview of compact, induced combustion, hot surface ignition gas furnaces for manufactured housing.

Warranty Information

Details the 15-year limited warranty on the heat exchanger and 2-year limited parts warranty.

Key Features

Highlights ease of installation, diagnostics, fuel savings, safety, and component quality.

Cabinet and Ratings Data

Cabinet Dimensions

Provides dimensions (A, B, C) and weights for various furnace models and cabinet sizes.

Performance Ratings

Lists input/output MBH, airflow, AFUE, temperature rise, blower specs, and wire size.

Filter Performance and Clearances

Filter Performance Guidelines

Details airflow capacity without filters and requirements for field-installed air filters.

Unit Clearances

Specifies required clearances to combustibles for various installation orientations.

Installation Accessories

Propane Conversion Kit

Information on the propane (LP) conversion kit, noting it's not required for this model.

Vent Termination Kits

Details concentric and sidewall vent termination kits for venting options.

Filter Racks

Lists side and bottom return filter racks for upflow and downflow applications.

Base Kits and Transition Kits

Describes combustible floor base kits and EAC transition kits for installation flexibility.

High Altitude Switches & Thermostats

Covers high altitude pressure switches and compatible room thermostats.

Blower Performance Data

Bottom Airflow Performance

Table showing blower airflow (SCFM) at various static pressures for bottom air intake.

Left Side Airflow Performance

Table showing blower airflow (SCFM) at various static pressures for left side air intake.