Assembly/commissioning
The AQiX water dosing system is set to the unit of “litres”
ex works.
The device is delivered with a standard ½“ hose connec-
on. This can be unscrewed and replaced with a dierent
tap connecon, such as with a bayonet coupling.
Standard hose couplings with 1/2“ or 3/4“ hose connecon
can be used as a quick-release or bayonet coupling.
Connect the water hose to the meter. The water hose may
not be pressurised.
Only connect the hose to the hose coupling. No hose may
be connected to the water outlet (7).
Aer every connecon made to the water hose, rst make
sure that the air can escape from the device.
• Press the “START/PAUSE” (12) buon to switch on the
device.
• Set the display to “0” with the “0.00 - Man.” (10) buon.
• Keep holding the “START/PAUSE” (12) buon unl the
water ows out without any interrupon.
Press the "START/PAUSE” (12) buon to start the metering.
You can interrupt the metering process. Press the "START/
PAUSE” buon to do this. Pressing the buon again starts
the metering process where it was interrupted.
Frequently used metering quanes can be saved by press-
ing the “M1” / "M2” (8+9) buons. Set the desired quanty
value with the “+” and “-” buon. Then hold “M1” / “M2”
for 2 seconds unl the value in the display ashes. Press
“M1” / "M2” to call up the stored value. It will appear in
the display
Press the “Man/0.00” buon (10). Then press “START/
PAUSE” (12). The water will run for as long as you hold
down the buon. The dispensed quanty of water is
shown in the display.
The water dosing system can be used with three dierent
units of measure: Litres, quarts and US gallons.
To switch between them, hold the “Man/0.00” buon for
5 seconds unl 0_ _ appears in the display. Set the desired
number for the respecve unit of measure using “+” and
“-”. Conrm each digit with the “START/PAUSE” buon. Fi-
nally press Play twice. The device switches o and changes
the mode.
Value 100 = litres | 200 = quarts | 300 = gallons
You can hold the device in your hand for metering or hang
it on the mixing bucket or on the mixing bucket of a mixer.
The device is hung between the water outlet (7) and the
retaining bracket (6)
The AQiX water dosing system is switched on using the
“START/PAUSE” (12) buon. The unit rst appears in the
display and then the last set quanty.
Adjust the metering quanty using both keys (11) “+”
and “-”. The water quanty can be set in increments of
0.1 litres. Keep the buon depressed to advance quickly.
Hanging on a bucket