ADJUSTMENTS
AND
TESTING
SIMPLA 50B-BT
SIMPLA 55BT
SIMPLA 65BT
SIMPLA 50BST
Doc. 10021896
Issued 09/2010
Ver. AB
Page 1 of 16
READ THE USE AND MAINTENANCE MANUAL
Electric System Testing
1. Disconnect the battery connector.
2. Check the functioning of the electric system switches,
motors, solenoid valve, contactors, power fuses and
thermal trip units.
3. Check the condition and tightening of all power cables:
contactors, fuses, motors, etc.
4. Check the functioning and condition of the potentiometer
and the base confirmation microswitches (water and brush
rotation) and working operation, and those for automatic
squeegee rise and descent (AUTOMATIC VERSION only).
5. Check the handlebars lever is centrally positioned and that
the threaded rod does not touch the measuring device
card located beneath the instrument panel (if it does touch,
adjust it within the plastic joints.
6. Check the condition and connections of the battery poles on
the battery connector.
7. Reconnect the battery connector.
Question and Answer IconNeed help?