pump to take the appropriate steps in order to avoid danger for the operator or for the
environment.
Store all chemicals in a safe place out of children’s reach.
Should any chemicals come into contact with your eyes, wash immediately with water. Contact
a doctor without delay and remember to take the container of chemicals with you.
If any chemicals are swallowed, do not provoke vomiting. Contact a doctor without delay and
remember to take the container of chemicals with you.
Operating pressure must never exceed the maximum toleration level of the pump (refer to the
“FEATURES AND TECHNICAL SPECIFICATIONS”
section).
“FEATURES AND TECHNICAL SPECIFICATIONS” section).“FEATURES AND TECHNICAL SPECIFICATIONS”
For the following points, please also refer to the documentation which is provided with the
control unit.
a)
Set the delivery pressure to zero on the control unit so that it enters its “bypass” status.
b)
Start up the pump so that it can prime.
c)
Set the control unit to its “pressure” position.
d)
Turn the pressure adjustment knob on the control unit until the required amount of pressure is reached.
WARNING
To allow the pump to prime quickly, follow the instructions at point (a) every time the pump is
drained of liquid.
We recommend checking the level of the oil during the initial hours of its operation and to top
up the liquid if necessary as instructed in the ‘
PRELIMINARY PROCEDURES’
section.
6. SWITCHING OFF AND STORAGE
6.1 SWITCHING OFF
«
CAUTION
Complete any operations required to switch off the machine that incorporates the pump as
recommended by its manufacturer.
No part of the pump must be in motion and no pipe must contain liquid under pressure.
a)
Set the delivery pressure to zero as described in the
“START UP”
section.
“START UP” section.“START UP”
b)
Switch the pump off.
6.2 STORAGE
«
CAUTION
Complete any operations required to store the machine that incorporates the pump as recommended
by its manufacturer.
WARNING
Refer to the use and maintenance manual for the machine that incorporates the pump. After use,
complete a cleaning cycle, making the pump take up clean water. Never store the pump with
pumped liquid inside it.
The pump is not frost proof.
In order to prevent the formation of ice inside the pump in cold areas, we recommend making the
pump take up a motor vehicle grade anti-freeze before starting the “storage” procedures (diluted
as instructed for the minimum temperature that the pump will be exposed to) and then drain it
completely, making it operate for a few minutes without taking up any liquid.
«
CAUTION
dispose of anti-freeze liquid correctly; do not throw it away in the environment.

Table of Contents

Other manuals for Comet IDS 1701

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Comet IDS 1701 and is the answer not in the manual?

Comet IDS 1701 Specifications

General IconGeneral
BrandComet
ModelIDS 1701
CategoryWater Pump
LanguageEnglish

Related product manuals