Overview

This document is an instruction manual for ComfortStar Split Type Air Conditioners, covering models CLA12CA-T, CLA12CD-T, CLA18CD-T, CLA24CD-T, CIP12CA-HT, CIP12CD-HT, CIP18CD-HT, and CIP24CD-HT. It provides essential information for installation, operation, and maintenance to ensure optimal performance and user safety.

Function Description

The ComfortStar Split Type Air Conditioner is designed to provide cooling, heating (for heat pump models), dehumidification, and fan-only ventilation for domestic environments. It consists of an indoor unit and an outdoor unit connected by refrigerant piping and electrical wiring.

Operating Modes:

  • Cooling Mode: Cools the room and reduces air humidity.
  • Heating Mode: Heats the room (for heat pump models). During heating, the appliance may automatically activate a defrost cycle to clean frost from the condenser and recover heat exchange function. This typically lasts 2-10 minutes, during which the indoor unit fan stops. A forced defrosting option is available for North American markets by pressing the ECO button 10 times within 8 seconds in heating mode.
  • Dry Mode: Reduces air humidity for increased comfort.
  • Fan Only Mode: Provides air ventilation without cooling or heating.
  • Auto Mode: Automatically selects the operating mode based on the room temperature.

Special Functions:

  • Timer ON/OFF: Allows automatic switching on or off of the appliance at a set time.
  • SWING Function: Controls the movement of horizontal flaps (up/down) and vertical deflectors (left/right) to adjust airflow direction.
  • TURBO Function: Activates quick cooling or heating with the highest fan speed for strong airflow.
  • MUTE Function: Operates the indoor unit at the lowest fan speed for a quiet experience. Not available in dry mode.
  • ECO Function: Automatically sets the operation to save energy, available in both cooling and heating modes.
  • SLEEP Function: Activates a pre-setting automatic operating program. After 10 hours, the air conditioner returns to the previously set mode.
  • DISPLAY Function: Switches the LED display on the indoor unit panel ON or OFF.
  • I FEEL Function (Optional): Enables the remote control to measure the temperature at its current location and send this signal to the air conditioner to optimize the temperature around the user. Automatically deactivates after 2 hours.
  • GEN Function (Optional): A specific function that can be activated and deactivated, with different operating gears (L3, L2, L1, OF).
  • SELF-CLEAN Function (Optional): Helps carry away accumulated dirt and bacteria from the indoor evaporator. Runs for about 30 minutes and then returns to the pre-setting mode. Available for some heating pump inverter appliances.
  • Gentle Wind Function (Optional): Closes vertical flaps to provide a comfortable gentle wind feeling.
  • Health Function (Optional): Initiates Ionizer/Plasma/Bipolar Ionizer/UVC Lights (depending on models) for air purification.
  • 8°C Heating Function (Optional): Automatically starts heating mode when the room temperature is below 8°C (46°F) and returns to standby when it reaches 9°C (48°F). Cancels automatically if the room temperature is higher than 18°C (64°F).
  • I SET Function (Optional): Allows users to memory their favorite temperature, mode, and fan speed settings for quick recall with one button press.
  • Child-Lock Function: Locks the remote control buttons to prevent accidental changes.

Important Technical Specifications

Temperature Operating Ranges:

  • Fixed Air Conditioner:
    • Room Temperature (Heating): 0°C~27°C (32°F~80°F)
    • Room Temperature (Cooling/Dry): 17°C~32°C (63°F~90°F)
    • Outdoor Temperature (Heating): -7°C~24°C (19°F~75°F)
    • Outdoor Temperature (Cooling/Dry - T1 climate): 15°C~43°C (59°F~109°F)
    • Outdoor Temperature (Cooling/Dry - T3 climate): 15°C~52°C (59°F~125°F)
  • Inverter Air Conditioner:
    • Room Temperature (Heating): 0°C~27°C (32°F~80°F)
    • Room Temperature (Cooling/Dry): 17°C~32°C (63°F~90°F)
    • Outdoor Temperature (Heating): -15°C~24°C (5°F~75°F) (Low temperature heating: -20°C~24°C (-4°F~75°F))
    • Outdoor Temperature (Cooling/Dry - T1 climate): 15°C~50°C (59°F~122°F) (Low temperature cooling: -15°C~50°C (5°F~122°F))
    • Outdoor Temperature (Cooling/Dry - T3 climate): 15°C~55°C (59°F~131°F)

Refrigerant Pipe Length and Additional Refrigerant:

  • Inverter Models (9K-36K Btu/h):
    • Standard Charge Pipe Length: 5m/16ft (or 7.5m/24ft for North American, etc.)
    • Maximum Distance (Indoor to Outdoor): 15m/49ft to 30m/98ft
    • Additional Refrigerant Charge: 15g/m to 30g/m
    • Max. Diff. in Level (Indoor to Outdoor): 10m/32ft to 20m/65ft
    • Type of Refrigerant: R22/R410A, R32
  • ON-OFF Models (9K-36K Btu/h):
    • Standard Charge Pipe Length: 5m/16ft
    • Maximum Distance (Indoor to Outdoor): 15m/49ft
    • Additional Refrigerant Charge: 15g/m to 30g/m
    • Max. Diff. in Level (Indoor to Outdoor): 5m/16ft
    • Type of Refrigerant: R22/R410A, R32

Torque Parameters for Pipe Connections:

  • 1/4" (Φ 6.35): 15-20 N·m (11.1-14.8 lbf·ft, 1.5-2.0 kgf·m)
  • 3/8" (Φ 9.52): 31-35 N·m (22.9-25.8 lbf·ft, 3.2-3.6 kgf·m)
  • 1/2" (Φ 12): 45-50 N·m (33.2-36.9 lbf·ft, 4.6-5.1 kgf·m)
  • 5/8" (Φ 15.88): 60-65 N·m (44.3-48.0 lbf·ft, 6.1-6.6 kgf·m)

Electrical Specifications (Reference):

  • Min. Circuit Ampacity (A): ≤8 to ≤32
  • Min. Wire Cross-sectional Area (mm²): 0.75 to 6.0
  • Socket or Switch Specification (A): 15 to 40
  • Fuse Specification (A): 15 to 55

Usage Features

  • Remote Control: The primary interface for operating the air conditioner, featuring a display for mode, temperature, fan speed, and other settings. It uses 2 AAA (1.5V) batteries.
  • Indoor Display: An LED display on the indoor unit shows timer, temperature, and error codes, along with indicators for Timer, SLEEP mode, unit ON/OFF, and power ON.
  • Emergency Button: Located on the indoor unit's electronic control box, this button allows basic operation (Cooling, Heating, Off) if the remote control fails.
  • Airflow Direction: Adjustable via SWING function for horizontal flaps and vertical deflectors. Manual adjustment of vertical deflectors is also possible.
  • Fan Speed: Selectable between Auto, Mute, Low, Low-Mid, Mid, Mid-High, High, and Turbo.
  • Temperature Setting: Adjustable using the up/down buttons on the remote control.
  • Child-Lock: Prevents unintended operation by locking the remote control.

Maintenance Features

General Cleaning:

  • Always shut down the machine and cut off power supply for at least 5 minutes before cleaning.
  • Do not flush the air conditioner with water.
  • Use a soft dry cloth or a wet cloth dipped in neutral detergent to clean the unit's surface. Avoid volatile liquids like thinner or gasoline.
  • Wipe frequently to maintain a clean appearance.

Filter Cleaning:

  • Regularly clean the air filter to prevent dust accumulation, which affects performance. Increase cleaning frequency in dusty environments.
  • Remove the filter screen, clean it with soapy water, and air dry it.
  • Avoid touching the fins of the indoor unit after removing the filter screen to prevent scratching.

Long-Term Shutdown:

  • Remove batteries from the remote controller.
  • Disconnect the power supply to the air conditioner.

Restarting After Long-Term Shutdown:

  • Clean the unit and filter screen.
  • Check for obstacles at the air inlet and outlet of both indoor and outdoor units.
  • Ensure the drain pipe is unobstructed.
  • Install remote controller batteries and check power.

Troubleshooting: The manual includes a troubleshooting guide for common malfunctions, possible causes (e.g., power failure, dirty air filter, refrigerant leaks, faulty components), and error codes displayed on the indoor unit (e.g., E1 for indoor room temperature sensor fault, E4 for refrigerant system leakage, E7 for outdoor ambient temperature sensor fault).

Disposal Guidelines (European):

  • The appliance contains refrigerant and potentially hazardous materials.
  • It must not be disposed of as household waste.
  • Options for disposal include designated municipal electronic waste collection facilities, retailer take-back programs (when buying a new appliance), manufacturer take-back, or certified scrap metal dealers.
  • Improper disposal can lead to hazardous substances leaking into the environment.