15
● Auto / Manual mode function
Auto Mode (ON): When booted with number one switch on, it operates with auto mode.
Room numbers are allocated sequentially by the ID number configured.
(Building # is fixed as #101, designated ID X '4' will be final channel of room #)
Ex) When ID = 1 configured
Channel 1 (Line1) = Block 101 unit 1
Channel 2 (Line2) = Block 101 unit 2
Channel 3 (Line3) = Block 101 unit 3
Channel 4 (Line4) = Block 101 unit 4
(1(ID#) X 4 = 4[ Last channel unit number is designated as 4])
Ex) ID = 79(max) configured
Channel 1 (Line1) = Block 101 unit 313