PumPs/PowerHeads
ViaAqua®PowerHeadPumps,theenergyefficientandversatilewaterpump.Theseutility
pumpscanbeusedforwet/dryfiltration,watercirculation,proteinskimmers,fountainsand/
orponds.Enhancedmotordesignandmagneticrotortechnologymakestheseunitsenergy
efficientandsilent,yetarepowerfulandreliable.
warning and safeguard
WARNING
» ThisproductmaycontainchemicalsknowntotheStateofCaliforniatocausecancerand/orbirth
defectsorotherreproductiveharm.Washyouhandafterhandlingtheproduct.
» Itisyoursoleresponsabilitytoverifythattheplugandreceptacleareclean/freeofmoistureandsalt
buildupatalltimes.Thereceptaclemustbefreeofwater,salt,calcium,andmagnesium.Failureto
dosomaycausereand/orlossoflife.
» Donotplugintoanextensioncordorpowerstrip.
» Adriploopmustbeusedwhenplugintoanyelectricaldevices.Adriploopispartofthecord
hangingbelowthereceptacle.
» ThenationalcoderequiresallaquariumequipmenttobepluggedintoaG.F.C.I.(GroundFault
CircuitInterrupter)electricaloutlet.IfyoudonothaveaG.F.C.I.,haveanelectricianinstalloneprior
tooperatinganyaquariumcomponents.
* Pleasereadandfollowtheseimportantsafeguardsandsafety
guidelines.
* ViaAqua®pumpmustbeoperatedfullysubmersedatalltimes.
* NeveroperateaViaAqua®pumpwithaelectronicwavemakeror
timingdevice.Assuchdeviceswillcausepermanentdamagetothe
pumpand/ordemagnetizetheimpeller.
* Whenoperatesthepumpinsideanaquarium,apreltermustbe
used.Failuretouseaprelterwillcausedamagetotheimpellerand/
orpump.
* Whenoperatesapumpinsideapondorfountain,alargeprelter
mustbeused.Failuretouseitswillcausedamagetotheimpeller
and/orpump.
* Routinemaintenanceisrequiredtoinsurethemaximumperformance
andthelongevityoftheViaAqua®pump.Seemaintenance
guidelines.
* Priortomaintenanceonanyelectricalaquariumapplianceor
maintenancetotheaquarium,youmustdisconnectallelectrical
aquariumdevices.
* Theuseofasurgesuppressorisstronglyrecommended.
Important
Failuretomaintainand/oroperatethepumpaccordingtothemanufacturer’sguidelinesand
directionswillcausepumpnottoworkproperlyormaycompletelymalfunction.Thiscould
causethelossofsh,plantsandanimals.Itisthefullresponsibilityoftheconsumerto
maintainboththeiraquariumsandpumptoinsureahealthyaquaticenvironment!
Drip
Loop
GFCI
ONLY