System Time
System Time Calibrate.
System Password
Password to enter the setting menu.
Tank & Borehole Sensor Detect Filter
On O: Enable the filter or not
Detect time (seconds): The tank water full or borehole water empty will
undergo detection for 10 seconds and then stop.
Restart time (minutes): The tank water goes to empty or borehole water
rises above the low water sensor for 5 minutes.
ESC Key for Startup/Stop
Inverter startup and stop can use On/O button or by esc key (press it for 3
seconds or more)
Factory Reset
Reset all settings to default value.
MPPT Arithmetic Setting
Input Password: 9589
PID/Automatic: Chose the MPPT Arithmetic
PID MPPT: need to Configure the Vmp voltage according to the solar array
Automatic: The inverter will automatically track the maximum power point
of solar array. The Vmp config parameter is not required.
Coe of Current
The coe of solar input, ac input and ac output current.
Accelerated Second of inverter startup
The frequency Increase time while the startup command is valid.
Time Calibrate
(H:M M/D/Y)
14 : 25 07 / 16 / 19
System Password
0 0 0 0
Verify PW Please
Time to Delay
Enable
Disable
State now: Enable
Tank Sensor
Detect 10 (s)
Restart 5 (m)
Once water full
Timer to Delay
Enable
Disable
State now: Enable
Factory Reset
Enter
Back
Esc Key Cancel
Solar Panel
556
Vmp voltage
Mppt Work Mode
PID Automatic
Automatic Mppt
Accelerated
XXXX
Sec of startup