34
HYBRID FUNCTION GUIDE
34
Display Note
‘‘ON(Working)’’ Inverter is working and ac output normal
‘‘OFF(On/O)’’ On/O button release
‘‘OFF (SPMCS)’’ Remote SPMCS control to Stop
‘‘OFF (Timer)’’ Inverter is out of working time
“OFF (PV Low Pow)“ Solar production is too low to operate
“OFF (Hybrid)“ AC input Error, hybrid mode switch failed
“Off (Tank)“ The water tank is full.
“OFF (Borehole)“ The pump is dry run and no water input to the pump, software
“OFF (DryRun Soft)“ Pump dry run, no water input to the pump, detected by software
“OFF(AC Out S-C)“ AC over the max current IGBT
“OFF (Sensor Err)“ AC output current sensor error
“Off (Mft Drive)“ Software error
“OFF (AC Out O-A)“ AC output over load
“OFF (Over Load)“ Solar input power over maximum power of inverter
“OFF (DC Over Vol)“ Solar input over voltage
“OFF (Over Temp)“ Inverter over temperature
“OFF (Ic Voltage)“ Power supply error
“OFF (Phase Lost)“ AC output phase lost
“OFF (Low Voltage)“ Solar input low voltage
“OFF (Locked)“ Remote SPMCS control locked the inverter
“OFF (AC P-G S-C)“ AC output phase to ground short circuit
“OFF (Capacitor)“ Lifetime of capacitor is out, requires a replacement
“AC-Out 3Ph FWD“ AC output 3phase forward
“AC-Out 3Ph REV“ AC output 3phase reverse
“AC-Out 1Ph FWD“ AC output 1phase forward
“AC-Out 1Ph REV“ AC output 1phase reverse
“W:System Time“ System time is not working warning
Waring Inverter continue working and ignore the Warning
“W:System E2PROM“ E2prom is not working warning
“W:Hybrid Low Vol“ No AC input warning
“W:AC O Unbalance“ AC output3phase is unbalance warning
“W:AC Phase Lost“ AC 3phase input phase lost warning