V100-VL400 User Manual – Leading Particulars
Suction valves 1st stage:
2nd stage:
Delivery valves 1st stage:
2nd stage:
Crankcase oil capacity:
Oil pressure:
Recommended Oil:
Intercooler air pressure:
Air delivery connection flange:
(to BS 101962 Table D)
Cooling water pressure, maximum:
Cooling water flow, nominal:
Intercooler water connections:
Shell Corena P100
V200A/V200W /V300A/V300W
2.2 bar 1.8 bar
All other 2-stage models
V100/V150
V100W/V150W
VL200/VL300
4
-
VL400
8
84
-
V200/V300/VL400
18 Litres
All other models
9 litres
12
5 inch (<2 bar)
14 litres/min
All water-cooled intercooler models
G
1
/
2
A
V200W V300W
W/DW
4.8 bar
4.5 litres/min 9 litres/min
VL400
4 inch (>2 bar)
All Models:
1.7 bar
All Models:
2 inch
V200/V300
2.5 inch
VL200/VL300
4 inch
V200/V300
4
2
4
V100/V150
2
1
2
V100 V150 V200 V300
Motor rating suffix F2: 18.5 kW 30kW 37kW 55kW
suffix F3: 22kW 37kW 45kW 63kW
VL200A (1.4-2 bar) VL200A (2-3.5 bar) VL300A VL400A (2.3-3.5 bar)
VL200DA VL300DA
V
L400A (1.4-2.7 bar)
VL400DA
Motor rating VL Models: 22kW 30kW 37kW 45kW