Addendum to Compaq Armada 1500
Maintenance and Service Guide
Addendum 255318-001 to Guide 284820-001 23
Table C-2
AT Commands
Command
Description
&Bn V.32 Auto Retrain. This modem always auto retrains.
0: Disable V.32 auto retrain—NOT SUPPORTED
1: Enable V.32 auto retrain (default)
&Cn Data Carrier Detect (DCD) Control. Data Carrier Detect is a signal from the modem to your
computer indicating that the carrier signal is being received from a remote modem. DCD
normally turns off when the modem no longer detects the carrier sign. This command
controls the modem’s usage of the DCD pin of the DTE interface.
0: Carrier detect always “ON”
1: Carrier detect “ON” only when carrier is present (Default).
&Dn Data Terminal Ready (DTR) Control. &Dn controls the modem’s usage of the DTR pin of the
DTE interface.
0: Ignore. The modem ignores the true status of DTR and treats it as always on. This
should only be used if your computer does not provide DTR to the modem.
1: If the DTR signal is not detected while in on-line data mode, the modem enters
command mode, issues OK result code, and remains connected.
2: If the DTR signal is not detected while in on-line data mode, the modem disconnects
(default).
3: Reset on the on-to-off DTR transition.
&F Load ROM Default Settings. &Fn loads the configuration stored and programmed at the
factory. This operation replaces all of the command options and the S-register settings in
the active configuration with factory values. This command is allowed only in the off-line
command state and will return an ERROR result code if entered while on-line. To load the
factory settings, this command must be issued by itself.
0: Restore factory defaults.
&Gn V.22bis Guard Tone Control. &Gn determines which guard tone, if any, to transmit while
transmitting in the high band (answer mode). This command is only used in V.22 and
V.22bis mode. This option is not used in North America and is for international use only.
0 Guard tone disabled (default).
1: Sets guard tone to 550Hz.
2: Sets guard tone to 1800Hz
&Jn Auxiliary Relay option.
0: The auxiliary relay is never closed (Default).
1: NOT SUPPORTED, responds ERROR
&Kn Local Flow Control Selection.
0: Disable flow control. Same as \Q0
1: Reserved
2: Reserved
3: Enables hardware flow control (RTS/CTS). Same as \Q3 (default).
4: Enable software flow control (XON/XOFF). Same as \Q1.
&Mn Asynchronous Communications Mode.
0: Asynchronous mode (default).
1: Reserved
2: Reserved
3: Reserved
4: Reserved
Continued

Other manuals for Compaq Armada 1500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq Armada 1500 and is the answer not in the manual?

Compaq Armada 1500 Specifications

General IconGeneral
BrandCompaq
ModelArmada 1500
CategoryLaptop
LanguageEnglish

Related product manuals