E
18
item 01 902
Specifications
Sensor high-precision semiconductor alcohol sensor
Detection range 0,000~0,199 % BAC;
0,000~1,990 ‰ BAC;
0,000~0,995 mg/l (BrAC)
Accuracy: +-0,010 % BAC; +-0,100 ‰ BAC; +-0,050mg/l
Power input 2x 1,5 V AAA battery (not included)
Response time warm-up time: 15 s, respone < 5 s
Model 01 902
Precaution
• When after drinking, it is recommended to last after 20 minutes, it
is because 20 minutes is approximately for alcohol to be absor-
bed into blood from the digestive organs, and residual alcohol
remaining in the mouth takes this long to dissipate.
• For accurate result, do not repeat next testing within 3 minutes
after last time.
• Do not smoke and eat for 20 minutes prior testing.
• Do not use chemicals to clean the tester directly.
• Do not blowing liquid into the breath pipe.
• Do not use any excitant substances near the tester, such as
paint, insecticides, alcohol.
• Do not place the tester in the closed environment with contami-
nated air.
• Modifying or tampering with the unit' s internal components may
cause a malfunction.
Regardless of whether the product is used, manu-
facturers and vendors will not bear any responsibi-
lity for the violations. For example: drunk driving
and high-altitude operations.
Each person reacts differently to alcohol, so the
test results are for reference only, which cannot
serve as the criteria in determining the outcome.