Trouble shooting
Possible Cause
Solution
Batteries are not fully
charged.
Recharge the battery by
leaving the UPS plugged
in.
The on/off switch is
designed to prevent
damage by rapidly
turning it off and on.
Turn the UPS off. Wait 10
seconds and then turn
the UPS on.
The unit is not connected
to an AC outlet.
The unit must be
connected to a 230Vac
50/60Hz outlet.
Circuit breaker is tripped
due to overload
Turn the UPS off and
unplug at least one piece
connected equipment.
Unplug the power cord of
the UPS then press the
circuit breaker knob.
Batteries are discharged
Allow the unit to recharge
for at least 4 hours.