SL
Wireless
Controller
Heating
Active
Stand-By
The SL controller has 3 operating modes. It has to be set to the required mode prior to the installation by using the
switches located at the back of the controller. These modes are:
Basic
Timer
Temperature Control
There are 4 light indicators located around the button showing the status of the controller.
For basic mode, the switches are set as shown below.
Controller functionality in basic mode:
Press button to activate heating, press button again to set controller to stand-by.
When heating is active, the 4 light indicators are green. After pressing the button, heating is set to stand-by; the indi-
cators will change from green to red for 4 seconds and then go off.
Please read this guide carefully and retain for future use and maintenance.
Installation and User Guide
1. Getting to know your SL wireless controller
3. Basic Mode
2. Pairing
In order to pair your heater with the controller you must:
Turn Heater ON
Within 20 seconds, hold the button on the controller until the orange segments are lighting up in a
sequence.
If the controller is flashing red when powered this shows there is a fault with the unit and it should be replaced.
In timer mode, switch 3 or 4 must be in the ‘ON’ position. This mode allows for 3
different settings which will alter the time period for each segment.
Switch 3 - Each time period represents 5 minutes.
Switch 4 - Each time period represents 10 minutes
Switch 3 & 4 - Each time period represents 15 minutes
4. Timer Mode
For timer mode, the switches are set as shown below.
60 MINS
45 MINS
30 MINS
15 MINS
Controller functionality in timer mode:
In timer mode, the controller acts as a 4 stage run-back timer. When the controller is in stand-by mode and button is
pressed, the first indicator segment will light up green and heating is activated. When pressed again the second segment
will light up and so on. Each segment is representing a time period that is selected when setting the switches.
In the example below, the only switch in the ‘ON’ position would be number 3. The button would be pressed four times to
activate four 15-minute segments resulting in the heater staying on for 1 hour. At the end of the last time period, the light
indicators will be red for 4 seconds and then go off. The controller is now in stand-by mode.
Question and Answer IconNeed help?

Do you have a question about the Consort SL and is the answer not in the manual?

Consort SL Specifications

General IconGeneral
BrandConsort
ModelSL
CategoryController
LanguageEnglish

Summary

Getting to Know Your SL Wireless Controller

Controller Modes and Indicators

Lists the three operating modes (Basic, Timer, Temperature Control) and mentions the 4 status indicator lights.

Pairing the Controller with Heater

Pairing Procedure Steps

Details the steps to pair the heater with the controller, including turning the heater on and holding the controller button.

Basic Mode Operation

Basic Mode Switch Settings

Illustrates the correct switch configuration for the controller to operate in Basic Mode.

Basic Mode Functionality

Explains how to activate heating and stand-by, and the indicator light feedback for each state.

Timer Mode Operation

Timer Mode Switch Settings

Shows switch settings for timer mode and details time period durations based on switch combinations.

Timer Mode Functionality

Describes the 4-stage run-back timer operation, activation sequence, and indicator feedback.

Temperature Control Mode

Comfort Period Temperature Control

Explains maintaining set room temperature, target setting range, and indicator changes based on temperature.

Setback Period Temperature Control

Details setback mode for frost protection, setting the setback temperature, and its indicator feedback.

External Input Functionality

External Input Connection and Effect

Describes connecting external inputs (timers, BMS) and how they affect controller modes and indicators.

Controller Installation

Powering and Wiring Requirements

Covers power options (mains 240Vac, 12Vdc), SELV requirements, and maximum wire size for installation.