TP500
PRODUCT MANUALS
normothermia
Question and Answer IconNeed help?

Do you have a question about the Contec TP500 and is the answer not in the manual?

Summary

Performance Parameters

Button and Parameter Setting

Button Operation Guide

Step-by-step instructions for device operation using buttons, including power on, measurement, and interface navigation.

Settable Parameters

Details on configurable settings such as sound prompts, temperature units (°C/°F), and measurement modes.

Mode Selection Note

Important clarification on selecting 'Body' mode for accurate human temperature measurement.

Product Packaging

Declaration of Conformity

Export Certificate

Medical Device Registration

Authorization Letter

Overview

The TP500 Infrared Thermometer is a non-contact device designed for measuring human body temperature. It offers a range of features and specifications that make it suitable for both professional and personal use.

Function Description

The TP500 Infrared Thermometer measures temperature by detecting infrared energy emitted from the body. It is designed for non-contact measurement, making it hygienic and convenient. The device performs a self-test upon startup and indicates any failures on the screen. It can measure body temperature in "Body" mode and skin temperature in "Object" mode. Users must ensure they select the correct mode for accurate readings.

Important Technical Specifications

Model: TP500 Display Range: 32.0°C ~ 43°C Max. Allowable Error:

  • 35.0°C ~ 42.0°C: ±0.2°C
  • <35.0°C or >42.0°C: ±0.3°C Max. Allowable Clinical Repeatability: <±0.3°C Resolution: 0.1°C Power Supply: DC 3V (2 AAA batteries) Measurement Time: <1s Display: LCD screen Normal Working and Storage Condition:
  • Working: 16°C ~ 35°C, ≤85% RH (no condensation)
  • Storage: -20°C ~ +55°C, ≤95% RH (no condensation) Memory: 30 groups of data

Usage Features

Turning On and Measuring:

  • Device Off State: Pressing the button turns on the device. It performs a self-test, enters the startup interface, and emits a beep sound. If the self-test fails, a failure prompt appears on the screen.
  • Device On State: A short press of the button initiates a measurement.

Reviewing and Setting Parameters:

  • Review Interface: A long press of the button from the device on state enters the review interface.
  • Parameter Setting Interface: From the review interface, a long press of the button enters the parameter setting interface.
  • Switching Items: In the setting interface, a short press of the button switches between items.
  • Adjusting Parameters: When the cursor is on the desired item, a long press selects it, and then a short press adjusts its parameter.
  • Saving and Exiting: After setting parameters, a long press of the button saves the settings and exits the interface.

Settable Parameters:

  • Sound Prompt: Toggle sound notifications.
  • Unit: Switch between °C (Celsius) and °F (Fahrenheit).
  • Mode: Users can switch to "Obj" (Object) mode for calibration. This setting is not saved, and the device automatically reverts to "Body" mode upon restart.

Important Note on Modes: The device distinguishes between "Body" temperature and "Object" temperature. "Body" mode measures human body temperature, while "Object" mode measures skin temperature. It is crucial to select "Body" mode when measuring body temperature for accurate readings.

Maintenance Features

Product Inspection: Refer to the maintenance instructions for product inspection before preparing for measurement.

Battery Management:

  • Long-term Storage: If the device will not be used for an extended period, remove the batteries to prevent leakage and potential device damage.
  • Battery Polarity: Pay close attention to the correct battery polarity during installation to avoid damaging the device.
  • Battery Type: Only single-purpose batteries should be used. Rechargeable batteries are not permitted.
  • Disposal: Do not dispose of used batteries by throwing them into fire. The disposal of waste batteries must adhere to local environmental protection regulations.

Product Packaging

Single Box Dimensions: 149.5 mm (length) x 96.8 mm (width) x 43.5 mm (height) Net Weight (per box): 130g Sealing (per box): 50 units Outer Box Dimensions: 58 cm (length) x 27 cm (width) x 35 cm (height) Gross Weight (per outer box): 6.5 kg

The TP500 Infrared Thermometer is manufactured by CONTEC MEDICAL SYSTEMS CO., LTD. and is certified under various international and national standards, including IEC60335-1, CISPR 14-1, and CISPR 14-2. It holds a Declaration of Conformity with Directive 2014/30/EU for electromagnetic compatibility and is registered as a non-medical device in some contexts, while also having medical device registration in China (Registration Certificate No. 20202070176). The product is approved for manufacturing and sale in China, with its certification valid until February 17, 2021, and its medical device registration valid until March 25, 2025.

Contec TP500 Specifications

General IconGeneral
BrandContec
ModelTP500
CategoryThermometer
LanguageEnglish