SURFACE PRIME
Error codes
E1 + Alarm:
1. A saucepan is not present in the cooking zone.
2. The saucepan is not suitable for induction cooking.
3. The diameter of the saucepan is less than 10 cm.
E2 + Alarm:
Internal operating temperature too high. The overheating protection system cuts out the power supply.
Check that there is sucient ventilation and wait a few minutes before restarting.
E3 + Alarm:
High voltage protection activated. The local power supply voltage is greater than 275V.
E4 + Alarm:
Low voltage protection activated. The local power supply voltage is less than 145V.
E5 + Alarm:
The main sensor is disconnected.
E6 + Alarm:
The pan temperature is too high, so food may burn. The power supply is interrupted for safety reasons.
Press On/O to turn o the cooktop. Wait a few minutes before restarting.
E7 + Alarm:
Communication error with the right and lower left cooking zones simultaneously or only with the lower
left cooking zone.
E8 + Alarm:
Communication error with upper left cooking zone.
E9 + Alarm:
Bluetooth connection error.