115V(100Vmin.-120Vmax.),
230V (200Vmin.-240Vmax.). 50Hz-60Hz.
3.2 DC Output
Power distribution configuration:
Model CUL-750B
DC O/P Load Max. 750W
+3.3V
24A
+5V 30A
+12V1 16A
+12V2 16A
+12V3 15A
+12V4 12A
-12V 0.5A
+5V
SB
3.0A
3.3 Protection
The power supply itself is designed with short circuit, over voltage and over load
protection functions described as below:
3.3.1 Short Circuit Protection
A short circuit on any DC output will cause the power to latch. The power
supply will withstand a continuous short circuit to the output without damage or
overseers to the unit. The +5V
SB
can be shorted indefinitely and will recover
automatically when the short is removed.
3.3.2 No Load Operation
No hazardous conditions or damage to the supply will occur with all of the DC output
connectors disconnected from the load.