Coolmay L02 Series PLC Programming Manual
Value shorter than the calculation
period can’t be run
0: positive action;
1: reverse action.
0: No input change alarm;
1: Input change amount alarm is valid.
0: No output change alarm;
1: Output change amount alarm is valid.
Do not turn ON bit2 and bit5 at the
same time
0: Auto-tuning doesn’t work;
1: Perform auto-tuning.
0: No output value upper and lower
limit setting;
1: The output value upper and lower
limits are valid.
Do not turn ON bit2 and bit5 at the
same time
Input filter constant (α)
0 means no input filtering
0 means as ∞ processing (no points)
0 means no derivative gain
0 means no differential processing
PID operation internal processing occupied, please do not change the data.
Input change amount
(increase side) alarm set value
(ACT): Valid when S3.+1 bit1=1
Input change amount
(decrease side) alarm set value
(ACT): Valid when S3.+1 bit1=1
Output change amount
(increase side) alarm set value
(ACT):
Valid when S3.+1 bit2=1, bit5=0
Output upper limit set value
(ACT):
Valid when S3.+1 bit2=0, bit5=1
Output change amount
(decrease side) alarm set value
(ACT):
Valid when S3.+1 bit2=1, bit5=0
Output lower limit set value
(ACT):
Valid when S3.+1 bit2=0, bit5=1
0: The input change amount (increase
side) does not overflow;
1: Input change amount (increase side)
overflow.
(ACT):
Valid when S3.+1 bit1=1 or bit2=1
0: The input change amount (reduction
side) does not overflow;
1: Input change amount (reduction side)
overflow.
0: The output change amount (increase
side) does not overflow;
1: Output change amount (increase side)
overflow.