40
4 times frequency: at most 2 channels, Max frequency is 24KHz;
6.2. Related device
1. For switching up/down counting of Single phase single counter
Type
Counter
number
Designated
device
Up
counting
Down
counting
Single phase single
counter input
C235
M8235
OFF
ON
C236
M8236
C237
M8237
C238
M8238
C239
M8239
C240
M8240
C241
M8241
C242
M8242
C243
M8243
C244
M8244
C245
M8245
2. For monitoring the up/down counting direction of Single phase
double counter and AB phase double counter
Type
Counter
number
Designated
device
Up
counting
Down
counting
Single phase double
counter input
C246
M8246
OFF
ON
C247
M8247
C248
M8248
C249
M8249
C250
M8250
AB phase double
counter input
C251
M8251
C252
M8252
C253
M8253
C254
M8254
C255
M8255
3. For High-speed counter function switching
Device name
Name
Content
M8198
Function switching
device
1 times/4 times switching device for C251/C252
M8199
1 times/4 times switching device for C253/C255